USER INTERFACE MODULE AND FUNCTIONS
Stand Alone Settings View/Change (continued)
To View/Change the Stand Alone Settings, press the
or
keys
on the
UIM
until the display shows
Stand Alone Settings
View/Change.
Press the
X (change)
key on the
UIM
, then select the channel to
view/change using the
or
keys. These keys repeat if held
down. When the channel to be viewed/changed is showing in the
display, press the
or
keys to change the value. These keys
repeat if held down. The display shows both the bit number (0-255)
and percentage (0-100%).
Please see the
Chase Select Table
when modifying chases.
To modify further channels, select the channel to view/change using
the
or
repeat keys, pressing the
or
repeat keys to
change the value.
When you have finished modifying channels, press the
(Yes)
key
to save changes or
X (Back)
key to restore the previous settings.
●
VIEW(Sig)/SET(NoSig) Chan Levels
To View the Channel Levels/Change the Stand Alone Settings, press
the
or
keys on the
UIM
until the display shows
VIEW(Sig)/SET(NoSig) Chan Levels
Press the
X (change)
key on the
UIM
, then select the channel to
change/view using the
or
keys. These keys repeat if held
down.
When the channel to be changed/viewed is showing in the display,
press the
or
keys to change the value. These keys repeat if
held down. The display shows both percentage (0-100%) and bit
number (0-255), and for channels 4 (Chase 1 Select) and 7 (Chase 2
Select) the chases selected.
Please see the
Chase Select Table
when modifying chases.
Notes:
this menu item is for this session use only, data is never saved.
the values can only be changed if the unit is not receiving data.
pressing the
X
or
keys returns to the main menu.
●
Restore Factory Default Settings
To restore the factory default settings, press the
or
keys on the
UIM
until the display shows
Restore Factory Default Settings.
Press the
X (change)
key on the
UIM
, then press the
(Yes)
key to
restore defaults or
X (Back)
key to exit.
The factory default settings are
DMX Address
1
ChromaZone Mode
46
Channel
Channels per Fixture
18 (CBankIP100) / 36 (CBankIP200/300)
Fixture number
1of2 (CBankIP100)/1of1 CBankIP200/300)
Chase patterns
12 (CBankIP100) / 12 (CBankIP200/300)
Channel 10
Grand Master for the 36 RGBs only
Input Smoothing
ON
Low Voltage Supply
ON
DMX Line Termination
OFF
If NoSignal use:
Stand Alone Mode
Stand Alone Settings
Ch.1 – 3
= 0 bits / 0%
Ch.4 = Chase 1 Select = Auto Chase
Ch.5 = Chase 1 Speed = 128 bits / 50%
Ch.6 = Chase 1 Level
= 255 bits / 100%
Ch.7 – 46
= 0 bits / 0%
Failure of the internal
ChromaBank IP 5 Amp, 5x20mm Power
Supply Fuse,
usually indicates an internal fault requiring servicing by
a qualified engineer.
If the front glass becomes cracked or broken, disconnect from the
mains immediately and have the unit repaired. Replacement glasses
are available from Pulsar.
The PMX/DMX connections (input and thru) are protected against
inadvertent shorts to 240Vac and static damage.
PORTABLE APPLIANCE TESTING -
The
Pulsar
ChromaBank IP 100, 200 and 300
may be safely Earth Bond and
Insulation Tested.
STANDARDS -
The
Pulsar ChromaBank IP 100, 200 and 300
comply with the following International and National Standards:
Electrical Safety -
IEC65, EN60065, BS415
EMC
- EN50081-1, EN55022, EN50082-1
Index of Protection
– IP65
Marking
Directive 93/68/EEC -
The
Pulsar
ChromaBank IP 100, 200 and 300
meet the EMC
Directive 89/336/EEC and the Low Voltage Directive
73/23/EEC.
GUARANTEE
- three years from the date of original purchase. The
guarantee covers defects in manufacturing workmanship and
materials. It is limited to parts and labour. The guarantee becomes
void if the product is: a) misused, b) not used in accordance with the
instructions, c) the cable connections are not made according to our
instructions if the unit is used in damp or wet environments, d) repairs
are made by unauthorised persons, e) the serial number label has
been removed or defaced. Pulsar's maximum liability shall not
exceed the price paid for the product. In the unlikely event of a fault
occurring, do not use without repair. Return the product, with a
description of the fault, to your supplier or direct to Pulsar for
immediate attention.
DIMENSIONS AND WEIGHTS
Code Unit
Width
Height
Depth Weight
mm
mm
mm
kg
CBankIP100 ChromaBank IP 100W 6 segment
598.0 132.0 132.0
5.3
CBankIP200 ChromaBank IP 200W 12 segment 1198.0 132.0 132.0
12.4
CBankIP300 ChromaBank IP 300W 12 segment 1198.0 132.0 132.0
12.4
OTHER INFORMATION
CHROMABANK IP 100
CHROMABANK IP 200