Red LED’s  

A

OVP, 

B

OVP, 

C

OVP 

(on unit PCB) indicates overvoltage protection status for a particular group: A, 

B, C.  In case of protection activation, a correspondent LED lights 
(

AOVP 

the group of A outputs etc.). 

 

 

 
 

 

Fig.3. The view of LED panel. 

 
 

4. 

Service and operation

.

 

 

4.1 Procedure in case of short-circuit (activation of SCP) of the power supply output. 

 

Outputs of the O1÷O9 power supply are protected against short-circuits with fuse-element safety device (inserts) 

or PTC. In case of damaging fuse-element safety device it is necessary to exchange the fuse (compliant with the 
original). 

If PTC polymer fuses protection was chosen, then automatic disconnection of the output voltage was signalled by 

switching off the green diode. It is then necessary to disconnect the load from the power supply output for the period of 
about 1 min. 

 

It is acceptable to change values of fuses to other than original, if not all outputs of power supply are used 
and Pmax is not exceeded.

 

 

4.2 Procedure in case of overload (activation of OLP) of the power supply output. 

Sections  A,  B,  C  are  equipped  with  the  PTC  protection  based  on  polymer  fuses.  In  case  of  overload  of  section 

with the current which exceeds value 1,6A, the overloaded section will be automatically disconnected. It is signalized by 
turnig  off  LED’s  of  overloaded  section.  Return  of  output  voltage  require  turning  off  the  overloaded  section  or  230V  AC 
supply for about 1 minute time. 

 
 

4.3 Maintenance. 

All maintenance operations can be performed after the power supply is disconnected from the power network. As 

for the power supply, it is not necessary to perform any special maintenance operations, but if the power supply interior 
is significantly dusty, it shall be vacum-cleaned by compressed air. In case of fuse replacement, the spare parts shall be 
the same as original ones.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for AWZ 09123

Page 1: ...PSU S 12V L 3A 9 FTA PTC TR MC AWZ 09123 v 1 0 Linear stabilized power supply unit EN Edition 1 from the 30th January 2011 Supercedes edition _____________...

Page 2: ...and operation 4 1 Short circuit protection 4 2 Overload protection 4 3 Maintenance 1 Technical description 1 1 General description Buffer power supply unit is designed for the supply of equipment req...

Page 3: ...circuit DC 3 P A B C voltage adjustments output voltage regulation for a particular group 4 OUTPUTS of power supply unit connector Tab 2 5 F fuse in the power supply circuit 230V AC 6 L N power suppl...

Page 4: ...4 Fig 2 The view of the power supply unit...

Page 5: ...status AC normal status lights failure status does not light OVP overvoltage protection status normal status lights failure status does not light Fuse F Bezpiecznik FA1 FC3 T 1A 250V F 500mA 250V Mech...

Page 6: ...230V AC shall be connected to L N terminals of the power supply The earth conductor shall be connected to the terminal marked by the earth symbol The connection shall be made by means of a three core...

Page 7: ...of about 1 min It is acceptable to change values of fuses to other than original if not all outputs of power supply are used and Pmax is not exceeded 4 2 Procedure in case of overload activation of OL...

Page 8: ...n item 5 may be prolonged if there is no technical capability to carry out the repairs and in the case that the equipment has been accepted conditionally due to the failing of the warranty terms by th...

Reviews: