CP20.245-R2 

 

 

 

 

CP-Series 

24V,

 

20A,

 

S

INGLE 

P

HASE 

I

NPUT

 

 

 

Aug. 2022 / Rev 1.1 DS-CP20.245-R2 EN  

All parameters are typ. values specified at 24V, 20A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 

www.pulspower.com   Phone +49 89 9278 0    Germany 

7/28 

 

6.

 

O

UTPUT

 

 
Output voltage 

nom. 

DC 24V 

23.8 - 25.2V 

 

The device is featured with a “soft output regulation characteristic” in order to 
achieve current share between multiple devices, when they are connected in parallel. 

The “soft output regulation characteristic” regulates the output voltage in such a 
manner that the voltage at no load is approx. 4% higher than at nominal load. 

Adjustment range 

 

See chapter 24.2 

 

Factory settings 

 

24.1V 

±0.2%, at 20A, cold unit (results to typ. 23.9V±0.2% 
at 24A and typ. 25.1V±0.2% at no load) 

Line regulation 

max. 

10mV 

85-300Vac 

Load regulation 

typ. 

1000mV 

Static value, 0A 

 20A; see Fig. 6-1 

Ripple and noise voltage 

max. 

100mVpp 

10Hz to 20MHz, 50Ohm 

Output current 

nom. 

20A 

Up to 60°C ambient temperature, see Fig. 16-1 

 

nom. 

15A 

At 70°C ambient temperature, see Fig. 16-1 

 

Derate linearly b60°C to +70°C, see chapter 16 

PowerBoost

*)

 

nom. 

24A 

Up to 45°C ambient temperature, see Fig. 16-1 

 

PowerBoost decreases linearly to nominal power b45°C and +60°C, see 
chapter 16 

Fuse breaking current 

typ. 

60A 

Up to 12ms once every five seconds, see Fig. 6-3 
The output voltage stays above 20V. See chapter 
24.1 for more peak current measurements. 

Overload behaviour 

 

Continuous 
current 

Output voltage > 13Vdc, see Fig. 6-1 

 

 

Hiccup

PLUS

®

 mode

**)

  Output voltage < 13Vdc, see Fig. 6-1 

Short-circuit current 

min. 

26A

***)

 

Load impedance <10mOhm, see  Fig. 6-1 

 

max. 

31A

***)

 

Load impedance <10mOhm, see  Fig. 6-1 

 

max. 

9.8A

***)

 

Average (R.M.S.) current, load impedance 50mOhm, 
see Fig. 6-2. 

 

min. 

55A 

Up to 12ms, load impedance <10mOhm, see Fig. 6-3 

 

typ. 

70A 

Up to 12ms, load impedance <10mOhm, see Fig. 6-3 

Output capacitance 

typ. 

8 000µF 

Included inside the power supply 

*)  

PowerBoost

 

This power/ current is continuously allowed up to an ambient temperature of 45°C. 

Above 45°C, do not use this power/ current longer than a duty cycle of 10% and/ or not longer than 1 minute every 10 minutes. 

**)  

Hiccup

PLUS

®

 Mode

 

At heavy overloads (when output voltage falls below 13V), the power supply delivers continuous output current for 2s. After this, the 

output is switched off for approx. 18s before a new start attempt is automatically performed. This cycle is repeated as long as the 

overload exists. If the overload has been cleared, the device will operate normally. See Fig. 6-2. 

***) 

Discharge current of output capacitors is not included. 

 

 

Fig. 6-1

   Output voltage vs. output current, typ. 

 

Fig. 6-2

   Short-circuit on output, Hiccup

PLUS

 mode, typ. 

 

Output Voltage

0

0

25

4

8

12

28V

16

20

24

40A

15

5

10

20

30 35

Output Current

Continuous

current

Hiccup

PLUS

mode

 

 

Output

Current

0

29A

18s

18s

18s

2s

2s

2s

t

Short -circuit

Normal

operation

Normal

operation

 

Summary of Contents for Dimension CP Series

Page 1: ...systems and plug connector terminals to allow device replacement while the application keeps running The CP20 245 R2 covers an extreme wide temperature range from 40 C up to 60 C providing full outpu...

Page 2: ...ed Enclosure 28 24 12 Mounting Orientations 29 The information given in this document is correct to the best of our knowledge and experience at the time of publication If not expressly agreed otherwis...

Page 3: ...ons require a reduction in output current Make sure that the wiring is correct by following all local and national codes Use appropriate copper cables that are designed for a minimum operating tempera...

Page 4: ...me unless otherwise noted www pulspower com Phone 49 89 9278 0 Germany 4 28 The maximum surrounding air temperature is 70 C The operational temperature is the same as the ambient or surrounding air te...

Page 5: ...1 65 1 63 1 63 At 20A Start up delay typ 450ms 420ms 440ms See Fig 3 2 Rise time typ 145ms 145ms 145ms At 20A const current load 0mF load capacitance see Fig 3 2 typ 160ms 160ms 160ms At 20A const cur...

Page 6: ...r Supply AC DC Battery N a Use a battery or a similar DC source A supply from the intermediate DC bus of a frequency converter is not recommended and can cause a malfunction or damage the unit b Conne...

Page 7: ...see Fig 6 3 The output voltage stays above 20V See chapter 24 1 for more peak current measurements Overload behaviour Continuous current Output voltage 13Vdc see Fig 6 1 HiccupPLUS mode Output voltage...

Page 8: ...c behavior 12ms 0 0 4 8 12 28V 16 20 24 70A 30 10 40 50 20 60 Output Current 7 HOLD UP TIME AC 100V AC 120V AC 230V Hold up Time typ 65ms 65ms 65ms At 10A see Fig 7 1 min 54ms 54ms 54ms At 10A see Fig...

Page 9: ...power supply in front of the decoupling device see also chapter 11 Contact closes As soon as the output voltage reaches typ 22Vdc Contact opens As soon as the output voltage dips below 22Vdc Short di...

Page 10: ...n assumption for a typical application where the power supply is loaded with 25 of the nominal load for 25 of the time 50 of the nominal load for another 25 of the time 75 of the nominal load for anot...

Page 11: ...ectrolytic capacitors Lifetime expectancy is specified in operational hours and is calculated according to the capacitor s manufacturer specification The manufacturer of the electrolytic capacitors on...

Page 12: ...mm2 max 6mm2 max 1 5mm2 American Wire Gauge AWG 20 12 AWG 24 10 AWG 26 14 Max wire diameter 2 4mm including ferrules 3 2mm including ferrules 1 8mm including ferrules Recommended tightening torque max...

Page 13: ...system is running Load I I L N PE 1a L N PE CP20 241 R2 73 Power Supply DC OK DC OK Output 24V 20A Input L N PE CP20 241 R2 73 Power Supply DC OK DC OK Output 24V 20A Input 1b 2a 3a 3b 2b Instructions...

Page 14: ...8 0 Germany 14 28 14 FRONT SIDE AND USER ELEMENTS Fig 14 1 Front side A Input Terminals plug connector N L Line input PE Protective Earth input B Output Terminals plug connector Positive output Negati...

Page 15: ...Criterion C Criterion A Criterion A Criterion A Criterion A Voltage interruptions EN 61000 4 11 0 of 200Vac 0V 5000ms Criterion C Voltage sags SEMI F47 0706 Dips on the input voltage according to SEMI...

Page 16: ...heric pressures from 80 47kPa Degree of pollution 2 acc IEC 61010 2 201 not conductive Vibration sinusoidal3 2 17 8Hz 1 6mm 17 8 500Hz 2g 2 hours axis IEC 60068 2 6 Shock3 30g 6ms 20g 11ms 3 bumps dir...

Page 17: ...y critical situations e g customer does not care about de rating requirements ambient temperature too high obstructs the airflow or install the unit in unsuitable mounting orientation There is no corr...

Page 18: ...ng set the cut off current settings to the value in the table below Fig 19 1 Dielectric strength A B C D A D C B B N L Input DC ok Earth PE Output Type test 60s 2500Vac 3000Vac 1000Vac 500Vac Factory...

Page 19: ...ble for US and Canada E File E198865 ATEX Agency Certificate Bureau Veritas EN 60079 0 Explosive atmospheres General requirements EN 60079 7 EN 60079 15 Equipment protection by type of protection e an...

Page 20: ...according to VDMA 24364 C1 L W for solvents and water based paints 21 REGULATORY PRODUCT COMPLIANCE CE EU Declaration of Conformity Trade conformity assessment for Europe The CE mark indicates conform...

Page 21: ...GHT Width 48mm Height 124mm without plug connectors Depth 127mm without plug connector The DIN rail depth must be added to the unit depth to calculate the total required installation depth DIN Rail Us...

Page 22: ...23 ACCESSORIES 23 1 ZM10 WALL WALL PANEL MOUNT BRACKET This bracket is used to mount the devices on a wall panel without utilizing the DIN Rail The bracket can be mounted without detaching the DIN ra...

Page 23: ...to trip fuses on faulty output branches or to start peak current demanding loads Solenoids contactors and pneumatic modules often have a steady state coil and a pick up coil The inrush current demand...

Page 24: ...haracteristic a setting to 24 0V results to an output voltage of 23 8V 0 2 at 24A and 25 0V 0 2 at no load See Fig 24 3 Output current min 24A At 45 C min 20A At 60 C min 15A At 70 C Reduce output cur...

Page 25: ...AC supply systems and may also be used on 24V branches MCB s are designed to protect wires and circuits If the ampere value and the characteristics of the MCB are adapted to the wire size that is used...

Page 26: ...load sharing between power supplies connected in parallel The Parallel use mode regulates the output voltage in such a manner that the voltage at no load is approx 4 higher than at nominal load See al...

Page 27: ...individual power supply units Therefore use the built in DC OK relay contact of the power supply Fig 24 7 Wiring diagram 1 1 Redundancy for 20A output current 24V 20A Load L N PE Failure Monitor I I L...

Page 28: ...phase to phase connection is allowed as long as the supplying voltage is below 240V 10 24 11 USE IN A TIGHTLY SEALED ENCLOSURE When the power supply is installed in a tightly sealed enclosure the temp...

Page 29: ...nded output current Curve A2 Max allowed output current results in approximately half the lifetime expectancy of A1 Fig 24 9 Mounting Orientation A Standard orientation Power Supply OUTPUT INPUT Outpu...

Reviews: