PULOON Technology Inc.
LCDM-1000
32
< Table 7-3 Over Reject by Double Detect Problem (Code: 3C) >
Case 1. PLATE D/D SENSOR deflected by external force.
: It should be positioned like the picture and attached to RVDT SENSOR
BLOCK and PIN properly.
: If the deflection is too serious, you should replace with new ones.
Case 2. Abnormal RVDT Sensor, Shaft Error in Production
: It is rare case but sometimes the sensor or shaft error in production
causes such a over-reject. It should be very serious and difficult
to fix that in customer’s house. It is recommended the RVDT should
be replaced with new one.
Over Reject
Meaning
44H
CODE
TABLE 7