Page 33
Installation
TM-1327GE Hardware
Figure 25.
GigE Ethernet Connector
Use at least cat5e UTP cables (cat6 cables are preferred). Refer to the
Cam2Net User’s Manual
for
details. JAI PULNIX recommends the use of shielded cables to reduce emissions and for CE/FCC
compliance. Double-shielded cables further reduce emissions.
7.2.3 Power Supplies and Power Cable Setup
Power Supplies
The TM-1327GE camera requires 12V DC power obtained through the 12-pin connector located on the
rear panel of the camera. JAI PULNiX recommends the following power supplies:
PD-12UU
100-240V AC/12V DC
1.2A universal voltage power supply,
US Plug
PD-12UUP
PD-12UU with12-pin connector
US plug
PD-12UE
PD-12UU
European plug
PD-12UEP
PD-12UU with 12-pin connector
European plug
If you are providing power through the 12-pin connector, the PD-12P, PD-12UEP and PD-12UUP
power supplies are available with the 12-pin mating connector already attached to the leads from the
power supply. You can connect the PD-12UU and PD-12UE power supplies to the JAI PULNiX power
cable using a terminal strip or directly.
When wiring the PD-12UU and PD-12UE power supplies directly, note the following:
•
Twist the lead ends together and tin-soldered for strength and electrical continuity.
•
Use shrink tubing or a similar insulator to prevent exposed leads from touching and shorting.
•
The +12V lead is marked with a red stripe or white lettering; be sure not to reverse the leads.
•
Make sure all connections are properly insulated to prevent shorting.
GigE
Summary of Contents for TM-1327GE series
Page 2: ......
Page 4: ......
Page 8: ...Page viii TM 1327GE Series Progressive Scan Camera...
Page 36: ...Page 28 GigE Series Camera Serial Commands TM 1327GE Software...