Revision 3
11
Problem solving
The W250 and W350 are manufactured for a severe environment and tasks, but the user must notice
that the machine contents of components which must be protected from hits and blows. Filter, sealings
connections are carefully chosen to serve the operator. Therefore must the machine be treated with
knowledge as to work correctly for many years.
Problem
Cause
Procedure
Motor don´t start No
current
Connect
the
machine
Defect cable
Change
Defect switch
Change
Motor stops immediately
Wrong fuse
Connect to proper fuse
Motor runs, but no suction Hose not connected
Connect the hose
Hose blocked
Clean the hose
Motor runs, but poor suction Hole on the hose
Change hose
Blocked filter
Change filter
Suction unit loose
Adjust
Dirt in the hose or
Clean the hose and intake
intake
Defect sealings
Change current sealing
Dust is blowing from motor Defect or loose filter
Adjust or change
Abnormal noise
Order service