10
Revision 3
Handling
The machine is for sucking and separating dry, not combustive dust with limit value of
explosion
>>>>
0.1mg/m
3
.
The motor is started by the switch. Dust laden air is then sucked through the inlet valve at
high speed via the suction hose. The air is slowed down by the cyclone and coarse dust
particles are separated out, partly by centrifugal force and partly by gravity. Air and finer
particles then pass through the tube filter where separation is made. The machine is designed
for filter cleaning by reverse air pulse.
The separated dust accumulates in the cyclone until the machine is switched off, when it drops
through the bottom flap into the plastic bag.
Using
Before using must the user be educated in handling the vacuum cleaner and the hazardous
dust.
The machine must be in top position. Place one foot on the trolley. Lift the whole tank-section
upwards along the 2 guides to the extremity, which means above the top and down to the end
position.
Connect the electric plug to an outlet with correct voltage (see the designation plate).
From time to time the filter must be cleaned. This must be done before changing the plastic
bag. Even appropriate when the working is completed or when there is poor suction.
Procedure: Cover the inlet, let the machine build up vacuum for a few seconds then quickly
push down on the key and release it slowly. Repeat the procedures 5-10 times. If suction
remains poor, the filter should be replaced.
The machine is equipped with a plastic bag of longopack type. When the bag is filled up
change of bag is done by adding a stripes on the plastic bag. Add one more stripes and cut the
bag in between. Adjust the size of bag by pulling down the plastic tube. Change of bag should
only be done after cleaning the filter. Changing the complete longopack is shown in figure 2.
Only use original parts.
By transporting the tank-section must be lowered to the lowest position (security). First clean
the filter and then change the plastic bag. Lowering is performed according to raising.
Change of filter
Risk of dust dispersion - Personal safety equipment
Health impairing dust can be spread during change of filter. Accordingly, the user should wear
protective glasses, protective gloves, and a breathing mask conforming to protection class
FFP3.
Shut off the machine and pull the plug out of the socket.
Summary of Contents for HTC 26D
Page 1: ...1 Revision 3...
Page 10: ...17 Revision 3 Reservdelar f r 120 V modell Spareparts for 120 V model...
Page 12: ...21 Revision 3 Reservdelar f r motorpaket 120 V Spareparts for engine package 120 V...
Page 13: ...22 Revision 3 Reservdelar f r motorpaket 120 V Spareparts for engine package 120 V...
Page 14: ...23 Revision 3...