HDBaseT Extender
PTN Electronics Limited
6
transmitter must connect to IR OUT of TPUH411R.
Step5.
Connect the RS232 port of the devices to be controlled and the receiver or the
transmitter.
Step6.
Connect with DC24V power adaptor(s) (One is enough if TPUH411T is
connected with adapter as its PoH function).
3.4 Application
TPUH411 has a good application in various occasions, such as computer realm,
monitoring, big screen displaying, meeting room, education and bank & securities
institution etc.
3.5 Twisted Pair Cable Connection
The twisted pair used in this extender MUST be a straight-through cable.
Notice
: Cable connectors
MUST be metal one, the
shielded layer of cable
MUST be connected to the
connector’s metal shell, to
make a better transmission.
TIA/EIA T568A
TIA/EIA T568B
Pin
Cable color
Pin
Cable color
1
green white
1
orange white
2
green
2
orange
3
orange white
3
green white
4
blue
4
blue
5
blue white
5
blue white
6
orange
6
green
7
brown white
7
brown white
8
brown
8
brown
1st
Ground
4--5
1st
Ground
4--5
2nd
Ground
3--6
2nd
Ground
1--2
3rd
Group
1--2
3rd
Group
3--6
4th
Group
7--8
4th
Group
7--8