Overhead Blower Model IN5130 

 

The  Model  IN5130  68KHz  AC  overhead  air  ionizer  is 

designed  to  cover  a  complete  workstation  and  to  protect 
sensitive electronic components from damage due to elec-
trostatic discharge (ESD). Using AC corona technology to 

make the air more conductive, Ptec™ ionizers produce a 

balanced  stream  of  positive  and  negative  air  ions  that 
never  need  calibration.  These  devices  are  used  in  many 
industries  and  manufacturing  applications  where  static 
electricity is a problem. 

 

About 

Ptec™  

Technology 

 

A  specialized  piezoelectric  high  voltage  transformer 

makes Ptec™ ionizers among the most  reliable  products 

available.  Ptec™  ionizers  are  designed  to  remain  in  bal-

ance  and  to  alarm  when  the  HV  output  affects  perform-
ance.  The  model  IN5130  overhead  static  eliminator  pro-
duces  a 68KHz  AC output  of  approximately 2200V and  a 
continuous  stream  of  balanced  air  ions.  Ionizers  that  use 

Ptec™ technology do not require calibration and only mini-

mal maintenance.  

 

Features 

 
 

On the front panel of the IN5130 are six LEDs. Three 

green  LEDs  indicate  that  power  is  applied  to  each  of  the 

three  Ptec™  HV  transformers.  The  red  LEDs  illuminate 

when  an  alarm  condition  occurs.  A  variable  fan  speed 
control and on-off switch are also on the front panel. The 
side panel of the ionizer has the IEC power input connec-
tor.   

Summary of Contents for IN5130

Page 1: ...Static Eliminators Instruction Manual Overhead Ionizing Blower Model IN5130...

Page 2: ...ation and Use Environmental Conditions 2 Set up and Placement 2 Mounting 3 Power Connection 3 3 Maintenance Periodic Maintenance 4 Cleaning Exterior 4 Cleaning Emitter Points 4 Emitter Point Replaceme...

Page 3: ...ltage transformer makes Ptec ionizers among the most reliable products available Ptec ionizers are designed to remain in bal ance and to alarm when the HV output affects perform ance The model IN5130...

Page 4: ...rill Adjustable air volume Power Requirements The Model IN5130 High Frequency AC overhead air ionizer is powered by an internal DC switching power sup ply that operates from 100 240 VAC 50 60 Hz The o...

Page 5: ...he ceiling or other structure Power Connection Connect the IEC Cable to the main unit and plug it in an AC socket Caution Use the appropriate IEC cable for the country of use Make certain the unit is...

Page 6: ...ll Clean it with a polyes ter wiper and a cleaning solution of 50 IPA electronic grade isopropyl alcohol and 50 de ionized water As semble it when it is dry Use the same method to clean the exterior o...

Page 7: ...nologies for infor mation about ordering replacement emitters The part num ber for emitters is listed below Replacement part Part Number Tungsten replacement emitters 22 6423 Because the IN5130 high v...

Page 8: ...chnical Support for repair assistance Troubleshooting The information below provides a reference for prob lems that may arise with your IN5130 overhead blower If you have other problems not covered be...

Page 9: ...ure 66 78 F 19 25 C Humidity 20 60 RH non condensing Airflow 115 x 3 CFM typical high speed Noise level 60dB A Distance 1 meter Indicators Power green LED Alarm red LED Controls On Off rocker switch f...

Page 10: ...on or acci dent In no event shall Transforming Technologies be liable for collateral or consequential damages To receive service under warranty please con tact Transforming Technologies Technical Supp...

Page 11: ...IN5130 Line Drawing 9...

Page 12: ...3719 King Rd Toledo OH 43617 P 419 841 9552 F 419 841 3241 info transforming technologies com...

Reviews: