Use the
ON/ZERO
key to
enter a parameter
WS1V Set Up Manual Rev. 7.8.30gll
8.2
Hold Function Setting
Hold 4 Parameter Setting
If
HOLD 4
is selected, refer to Note 4 to key
in the Parameters
Page 20
ON/ZERO
⇒
Increment digit (from 0 to 9)
TARE
⇒
Confirm / enter key
HOLD
⇒
Move the cursor to the right
= Hold function disabled.
=
“Peak hold” mode
(active when the weight on the platter is over 10d.)
The scale shows the maximum weight value detected from the continuously changing
weight values. Press any key to exit the hold function.
=
“Stable hold 1” mode
(active when the weight on the platter is over 10d)
When the scale becomes stable, the display shows the current weight value. Press any
key to exit the hold function.
=
“Stable hold 2” mode
After the scale is stable, the display shows the current weight value. Re-zero the scale to
exit the hold function.
4
=
“Animal Weighing” mode
(active when the weight on the platter is over
10d)
Refer to NOTE 4 to key in the stabilisation range and the timer parameters. When the
scale becomes stable, the display locks on the current weight value. The scale will
unlock and exit the hold function when the weight is below 10d or the scale is rezero'd.
Hold function setting
Use
ON/ZERO
key to key in the a parameters
Default setting = 0
0
⇒
Hold function disabled
1
⇒
“Peak hold” mode
2
⇒
“Stable hold 1” mode
3
⇒
“Stable hold 2” mode
4
⇒
“Animal Weighing” mode
Hold function setting
LCD displays the last current setting
Press the
TARE
key to
complete or to advance to
HOLD 4 Parameters
Back to weighing mode
00000
Press the TARE key to
complete entry and return
to weighing mode