J600R Instruction Manual
PST TEMS (Cont)
F. Programming Features
Start Enable
- Press UP until you see this page displayed. This page is used for
initiating the auto start from the GDT. Press UP to start the turbine. Another option for
starting the turbine is from the transmitter. Cycle the throttle and trim to minimum, then
place trim to max. Move the throttle stick to max and then back to min. The start
sequence should initiate if the stick/trim movement are done within 5 seconds. More
details of startup are in the Auto Start section.
Show Shutdown Data
- Press UP until you see this page displayed. Press ENTER to
select the page. The page is a freeze frame of the turbine condition at the point of
shutdown. The displayed values are showing what the TEMS was reading at the time of
shutdown. You can see what caused the shutdown, and also what the other readings
were at the time. “*” is displayed beside the cause of shutdown. (see the GDT
Diagnostics Display Interpretation section for details). The data will be retained even if
the TEMS is switched off and on again until the next shutdown. To exit back to the main
menu, press UP or wait for ten seconds.
Prime Pump Feature
- To ensure a successful auto start, the pump and fuel lines
should have fuel in them right up to the engine inlet. This is achieved y running the
pump to fill the lines.
Caution
: Do not over prime the engine as this can cause a hot
start. After the first setup of the system, the fuel pump may be dry and before priming,
the pump needs to be fed with a small initial amount of fuel. Use pressure to initiate the
flow of fuel to the pump before priming. It is advisable to disconnect the delivery line to
the turbine and redirect it to an external fuel container. Run the pump a few seconds to
circulate fuel in the system then reconnect the fuel line.
Press UP until you see this page displayed. Press ENTER to select the function.
Pressing the UP button will start the pump running at idle. To stop the pump, press UP
again. The display will return to the menu page automatically. To perform the priming
function again, repeat the sequence.
Setting of Ramping Values
- This option is open to the user but the default parameters
are recommended. Use the values as set from factory as shown on data sheet at the
end of this manual. The numbers can be simply interpreted as time (fraction of second)
required for ramping. The higher the number, the longer it takes to ramp thus slower
ramping. This feature is useful for fine tuning the J600 at different atmospheric
conditions.
Physical Adjusts
- Press UP until you see this page displayed. Press ENTER to
access the sub-menus below:
-
View Runtime & Start
- From this menu, press ENTER to display the turbine runtime
and number of starts. Theses values can only be reset by factory representatives after
engine service.
Copyrights
©
PST Jets Co., Ltd. -
16
- Version 1.5.3.1/2005