PSsystec SMARTbox IO Agent User Guide
-
Jumper must be set on the
Smartbox (during production)
-
It creates an event
c8y.ConfigAin=0
Enable the extra analogue Input
Note:
-
Jumper must be set on the
Smartbox for NTC and different
Jumpersetting for 0..20mA
(during production)
-
It creates and measurement
The settings are as follows:
0 – disabled
1 – NTC
2 – 0…20mA
Mini,DP, CubeIO
>2.3.x
c8y.DinLogic=0
Define the Logic of DIN Input
0 = NO
1 = NC
Mini,DP, CubeIO
>2.3.x
c8y.cycle=900
Define the send measurement cycle of the
extra analogue Input
Mini,DP, CubeIO
>2.3.x
c8y.ditext=<Name>
Define the Text of the event by DIN
Mini,DP, CubeIO
>2.3.x
c8y.ditype=<Name>
Define the type of the event by DIN
Mini,DP, CubeIO
>2.3.x
c8y.adcseries=<Name>
Define the Series of Measurement by AIN
Mini,DP, CubeIO
>2.3.x
c8y.adctype=<Name>
Define the Type of Measurement by AIN
Mini,DP, CubeIO
>2.3.x
c8y.LocationCycle=0
Define the Location update in min
If it is set to 0, then Location is derived
only at startUp.
all
>2.3.x
c8y.min=0
Define the Min of AIN Value conversion (if
AIN is set to 0…20mA by jumper)
Mini,DP, CubeIO
>2.3.x
c8y.max=0
Define the Max of AIN Value conversion
(if AIN is set to 0…20mA by jumper)
Mini,DP, CubeIO
>2.3.x
c8y.GPS=0
If GPS Hardware option is available you
can enable the GPS function by setting 1
and disable by settings 0. Note:
-
The locationcycle is also valid for
GPS enabled.
-
If GPS=0, the cellular location
determination is active
All with GPS
Option
>1.3.4
DeleteTenant
>1.3.4
Note:
All other configuration settings which you will get with the Snapshot are only for
Information and refers to internal settings.
Note: To set a configuration proceed as follows, put all statements in a new line
e.g.
c8y.DinLogic=1
c8y.min=1
press save
Use the Built-In IOs
____________
1. Note that the SMARTbox Mini supports:
-
1 x Digital Input (DIN)
-
1 x AIN (NTC,0..20mA)
Note the activation of NTC or 0..20mA must be defined during production