background image

 

  

TSC 1500

 

 

11 

 

 
Din Assignment: 
 
Relay Board 

S1 

S2 

S3 

S4 

S5 

S6 

  

On 

On 

On 

On 

On 

On 

Board is Mater is in Standard Operating Mode (1) 

On 

On 

On 

On 

On 

Off 

Password Reset Mode (2) 

On 

On 

On 

On 

Off 

On 

Reset all settings (Except password) (3) 

On 

On 

On 

On 

Off 

Off 

Programming enable mode (4) 

Off 

On 

On 

On 

On 

On 

Slave Mode Address #1 

On 

Off 

On 

On 

On 

On 

Slave Mode Address #2 

Off 

Off 

On 

On 

On 

On 

Slave Mode Address #3 

On 

On 

Off 

On 

On 

On 

Slave Mode Address #4 

Off 

On 

Off 

On 

On 

On 

Slave Mode Address #5 

On 

Off 

Off 

On 

On 

On 

Slave Mode Address #6 

Off 

Off 

Off 

On 

On 

On 

Slave Mode Address #7 

On 

On 

On 

Off 

On 

On 

Slave Mode Address #8 

Off 

On 

On 

Off 

On 

On 

Slave Mode Address #9 

On 

Off 

On 

Off 

On 

On 

Slave Mode Address #10 

Off 

Off 

On 

Off 

On 

On 

Slave Mode Address #11 

On 

On 

Off 

Off 

On 

On 

Slave Mode Address #12 

Off 

On 

Off 

Off 

On 

On 

Slave Mode Address #13 

On 

Off 

Off 

Off 

On 

On 

Slave Mode Address #14 

Off 

Off 

Off 

Off 

On 

On 

Slave Mode Address #15 

Notes: 

 

 

 

 

 

 

(1)- Normal Operating Mode- Options 1,3,4,5,6,7,8 (programming modes see pg11-13) on the keypad are inactive. 

(2)- Password reset- To reset the password you have to set the dip switch, remove power, press and hold switch 
(S1), Apply power. After about 5 seconds when LED's start blinking the settings reset is complete. 

(3)- Reset all settings- To reset all the settings, set dip switches, remove power, press and hold switch S1, apply 
power.  After about 5 seconds when the LED's start blinking the settings reset is complete. 

(4)- Programming enable mode- Enables Options 1,3,4,5,6,7,8 (pg 11-13) on the keypads.  Note that the power to 
the board has to be cycled after the dip switch setting has been made to enable this mode. 

Keypad 

S1 

S2 

S3 

Keypad 

On 

On 

On 

OFF 

On 

On 

On 

Off 

On 

Off 

Off 

On 

On 

On 

Off 

Off 

On 

Off 

On 

Off 

Off 

Off 

Off 

Off 

Summary of Contents for TSC 1500

Page 1: ...Installation Instructions Please read all instructions before attempting installation or operation of these units SAVE THESE INSTRUCTIONS FOR FUTURE USE PUBLICATION NO 8 5 1 7 5 4 5 3 1 F E B U R A R...

Page 2: ......

Page 3: ...TSC 1500 1 Table of Contents Section Page No Introduction 2 Cautions and Warnings 3 Specification Sheet 5 7 Installation 8 Programming Operation 12 Trouble shooting 15...

Page 4: ...ently operate all equipment in the gymnasium easily and efficiently Controls for backstops curtains mats batting cages scoreboards and even lights are available at the touch of a button TSC 1500 was d...

Page 5: ...TSC 1500 3...

Page 6: ...ops and or curtains being controlled in order to minimize wiring Determine location for keypad Keypad should be located at a convenient height for authorized users Keypad must be located such that the...

Page 7: ...TSC 1500 5...

Page 8: ...TSC 1500 6...

Page 9: ...TSC 1500 7 NOTE Master board shown Slave board will not have 12V hooked to keypad All 12V power is to be fed off of the master board to keep from back feeding power in the system when daisy chained...

Page 10: ...rom electrical noise introduced by 110v AC wiring other voltages and signals which may be present in the building infrastructure 1 The main 110v power feeds from the breaker panel to the RB should hav...

Page 11: ...e location for all device neutrals on the third incoming line e Terminal L4 is the location for all device neutrals on the forth incoming line Note Ground connections can be made to any open GND termi...

Page 12: ...ings Once the system is wired then it can be set up The din switches must be set on all relay boards and key pads Each unit comes as a default of master or keypad one See the following page for din se...

Page 13: ...12 Off On Off Off On On Slave Mode Address 13 On Off Off Off On On Slave Mode Address 14 Off Off Off Off On On Slave Mode Address 15 Notes 1 Normal Operating Mode Options 1 3 4 5 6 7 8 programming mo...

Page 14: ...Mode If code is incorrect you will hear a long error beep and LED will turn Solid Red Backstop Activate Backstop Press Backstop LED will turn Solid Yellow then enter two digit code 01 99 LED will flas...

Page 15: ...llow Enter two digit code 01 99 LED Flashes Green and two beeps Enter three digit device code 001 through 160 4 Beeps for confirmation Keypad will go back to command mode How to remove a device from a...

Page 16: ...then existing 4 digit code double beep and LED will flash yellow Then enter new 4 digit code 4 beeps for confirmation Keypad will go back to locked state enter new code to go to command mode Timer Not...

Page 17: ...TSC 1500 15 Passcode _____________ Notes 4321...

Page 18: ...Performance Sports Systems 9200 E 146th Street Noblesville IN 46060 800 848 8034 www perfsports com...

Reviews: