LD160 REV.E1-1
PSM LD16x vehicle loop detector installation guide
1.
Pin connections
MODEL NO.
PIN
161
162
163
1
110 VAC, LINE
230 VAV, LINE
12~24 VADC
LD-161
1
110 VAC, NEUTRAL
230 VAC, NEUTRAL 12~24 VADC
3
Output B Relay (N.O.)
Output B Relay (N.O.)
4
Chassis Ground
Output B Relay (COM.)
5
Output A Relay (COM.) Output A Relay (COM.)
6
Output A Relay (N.O.)
Output A Relay (N.O.)
7
Loop
Loop
LD-162
8
Loop
Loop
LD-163
9
Output B Relay (COM.) Chassis Ground
10 Output A Relay (N.C.)
Output A Relay (N.C.)
11 Output B Relay (N.C.)
Output B Relay (N.C.)
2.
Front panel LED and switch
(1) POWER
:
POWER RED LED
→
On= Power applied to detector.
;
Off = No power or fuse is
bad.
(2) DETECT
:
DETECT GREEN LED
→
On = Vehicle being detected
;
Blinking = Loop Failure.
(3) SWITCH 1(SENSITIVITY)
:
Selections of sensitivity are from 0 to 9 and A to F where 0
stands for the lowest sensitive and F is the highest sensitive.
Unit
:
-
ΔL/L × 100
﹪
SENSITIVITY LEVELS
LEVEL 0
2.56
LEVEL 4
0.48
LEVEL 8
0.12
LEVEL C
0.030
LEVEL 1
1.28
LEVEL 5
0.32
LEVEL 9
0.08
LEVEL D
0.020
LEVEL 2
0.96
LEVEL 6
0.24
LEVEL A
0.06
LEVEL E
0.015
LEVEL 3
0.64
LEVEL 7
0.16
LEVEL B
0.04
LEVEL F
0.010
(4) SWITCH 2(DIP SWITCH)
:
1.
DIP 1 & DIP 2 FUNCTION
:
DIP NO.
DIP MODE
FUNCTION
DIP 1
□■
ON
2 seconds delay for the relay. It will be no output for a vehicle with a speed
that is faster than 8 Km/Hr.
DIP 2
□■
ON
Increase detector’s sensitivity to avoid the failed detection. Especially in the
case of trailer or trucks.
2.
DIP 3 & DIP 4
-
OUTPUT B MODE
:
DIP NO.
DIP 3
DIP 4
OUTPUT B MODE
DETECT
DIP MODE
OFF
■□
OFF
■□
Pulse on entry
Output B mode
□■
ON
OFF
■□
Pulse on exit
Output B mode
OFF
■□
□■
ON Presence mode
Output B mode
□■
ON
□■
ON Output B will set to the presence mode when the loop failed.
3.
DIP 5 FUNCTION
:
DIP NO.
DIP 5
PRESENCE MODE
DIP MODE
□■
ON
Continuous detect output is maintained as long as the vehicle remains on
the loop.
OFF
■□
Hold time of 5 minutes for any vehicle detected.