Step 6: 

 
Once the edit to the Setup.ini file for the microPMU has been made, upload the new file via USB (see 
the microPMU Instruction Manual for details on uploading the setup file). 
 
Once the microPMU boots up with the new Setup.ini file, from the 

display’s 

home screen tap on System 

> Date/Time. On this screen tap to edit any one of year, month, day, until the date matches the current 
year, month and day. 
 

 

 
After making the edits, tap on the yellow home icon. This will prompt a message asking to confirm or 

cancel the time change. Confirm with the ‘

YES

’ option and the microPMU will reboot itself.

 

 

Step 7: 

 
Apply the firmware update via USB (see the microPMU Instruction Manual for details on applying the 
firmware file). 
 
Once the firmware update is complete and the device has rebooted, verify the firmware version number 
reported by the device matches version number in the name of the update file. 
 

Step 8: 
 

Shut down the microPMU completely using the same instructions as given for the step before 
disconnecting the MS1/GPS1 modules. After the device is shut down, physically reconnect the MS1 and 
GPS1 modules and restore input power to the microPMU. Finally, check the date reported by the 
microPMU 

reflects today’s date

 
 
For any further questions or concerns please contact PSL at [email protected] or by phone 
at +1-510-522-4400. 