148
Psion Teklogix NEO Hand-Held Computer User Manual
Chapter 5: Configuration
Decoded (Internal) Scanners
CLSI Editing
When enabled, this parameter strips the start and stop characters and inserts a space after the
first, fifth, and tenth characters of a 14-character Codabar symbol.
NOTIS Editing
When enabled, this parameter strips the start and stop characters from decoded
Codabar symbol.
Length Restriction
Refer to “Length Restriction” on page 142 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page 142 for details.
5.13.2.13 MSI Plessey
Enabled
Set this parameter to
on
to enable “MSI Plessey”.
Set Length L1 And Set Length L2
Lengths for “MSI Plessey” can be set for
Any length
,
Length within a range
,
One discrete
length
or
Two discrete lengths
. The length of a code refers to the number of characters (i.e.,
human readable characters), including check digit(s).
Double-tapping on this parameter displays a dialog box labelled
Set Code Lengths
where
you can define the code length that will be recognized by your scanner.
Choosing
One discrete length
allows you to decode only those codes containing a selected
length. Choosing
Two discrete lengths
allows you to decode only those codes containing two
selected lengths.
Length within a range
allows you to decode a code type within a specified
range from
6
to
55
.
Check Digits
Double-tapping on this parameter displays a dialog box in which you can choose
One
or
Two
check digit(s).
If this parameter is set to
One
, it is assumed that the last digit is a check digit. If “Check
Digits” is set to
Two
, it is assumed that the last two digits are check digits.
Note: Symbol length does not include start and stop characters.