background image

 

 

Summary of Contents for PlantPen/N-Pen N 110

Page 1: ......

Page 2: ...he specifications of the device However deviations cannot be ruled out Therefore a complete correspondence between the manual and the real device cannot be guaranteed The information in this manual is...

Page 3: ...on 12 4 3 Nitrogen nutrition 13 5 Getting started 14 5 1 Calibration 14 5 2 Measurement 14 6 Control menu tree 15 7 USB Connection 20 8 Bluetooth connection 21 8 1 Bluetooth pairing 21 9 FluorPen soft...

Page 4: ...Page 4 14 Troubleshooting and Customer Support 33...

Page 5: ...instructions in this guide Always follow corresponding manuals while working with the N Pen device or doing the maintenance It is forbidden to interfere with the hardware or software of the N Pen dev...

Page 6: ...nts Rugged and compact N Pen can be used for plant biology research or for education Due to an inbuilt GPS module and splash proof cover is N Pen suitable for field experiments The measurement is non...

Page 7: ...en 1 1 Windows 7 and higher Battery Li Ion rechargeable battery Capacity 2000 mAh Max charging current 0 5 A Charging via USB port PC power bank USB charger etc 70 hours typical with full operation Lo...

Page 8: ...C ID T9J RN42 Europe ETSI EN 301 489 1 V1 8 1 ETSI EN 301 489 17 V2 1 1 ETSI EN 300 328 V1 7 1 Canada IC RSS 210 low power comm device Certification number 6514A RN42 EMC USA FCC CFR47 Part 15 subclas...

Page 9: ...Page 9 3 DEVICE DESCRIPTION Fig 1 Device description...

Page 10: ...manufacturer Also check the carton for any visible external damage If any damage is found notify the carrier and the manufacturer immediately The carton and all packing materials should be retained f...

Page 11: ...region of visible spectrum Fig 2 Reflectance spectrum of green leaves roughly complements the absorption spectrum compare A and B in Fig 2 indicating that the presence of chlorophyll is critical for...

Page 12: ...rom average reflectance values and to predict the relative N content in dry matter of plants or the postharvest grain N content Due to differences in leaf structure of various crops formulas for calcu...

Page 13: ...is set equal to 0 as follows 1 NDGI 0 65 indicates 100 N nutrition state N 100 2 NDGI 0 25 indicates 0 N N 0 3 If 0 65 NDGI 0 25 then nutrition state is calculated as N NDGI 0 25 250 As a general rul...

Page 14: ...s For calibration use white reflectance standard It is part of leaf clip Turn ON device hold SET button for 1 sec Close the leaf clip white standard is on bottom part of the leaf clip Go to Calibratio...

Page 15: ...shows the Main Menu first level Sub Menus and second level Sub Menus The blue color represents the Main Menu and its Options The yellow color represents the first level Sub Menus and their Options The...

Page 16: ...Page 16...

Page 17: ...Page 17...

Page 18: ...Page 18...

Page 19: ...Page 19...

Page 20: ...ease follow steps below in Fig 6 Fig 6 How to connect N Pen with PC A connector on the N Pen device B Portion of the USB cable with pins C E Position the cable horizontally and line up the green circl...

Page 21: ...tooth documentation for more information Bluetooth must be switched on and be visible on both devices To pair the N Pen with another Bluetooth device such as a computer ensure that Bluetooth is switch...

Page 22: ...Fig 8 Add a device 4 Selecting the N Pen Select PSI N Pen icon Click Next Fig 9 5 Starting the Pairing Process This step is different for old and new version of the N Pen that are equipped with dispa...

Page 23: ...tion code is not important for the BT connection Select Next 6 Completing the N Pen Pairing Select Close Fig 12 The Bluetooth pairing is now complete and the next step is to open the program FluorPen...

Page 24: ...the file SN txt which is included on the enclosed USB flash disk Please Note it is not possible to download data from the N Pen device without software registration 3 Switch on the N Pen and enable B...

Page 25: ...y Erases data from the N Pen memory Online Control Online control of N Pen device Attach GPS File Used for download data from GPS module active only in version N Pen 100 MENU Setup Device ID Detects t...

Page 26: ...opened If the box is checked the downloaded data are added to that of the current opened experiment Data GPS Visible This option is active only in older version N Pen 100 In new version the GPS data...

Page 27: ...Control Protocols and Values These functions are not available for N Pen 9 3 DATA TRANSFER AND EXPORT 1 Perform a measurement with your N Pen 2 Click the Download icon or select Device Download 3 The...

Page 28: ...ware update download all your data from the N Pen memory to the computer 1 Starting Update Select Setup Update Firmware From File Fig 19 2 Warning Select OK to start update Fig 20 3 Selecting bxn file...

Page 29: ...le 4 Finishing Upload Select OK to start uploading of the update Fig 22 The bottom bar indicates the upload progress Fig 23 Fig 23 Uploading process Press OK to finish upload Fig 24 Fig 22 Data loss w...

Page 30: ...per panel changes as shown on Fig 25 3 If the picture on the display of the device does not change then proceed to Accessories GPS Location selection in the menu and manually map the GPS by pressing S...

Page 31: ...connect to USB port see instructions on pg 20 2 Downloading Data from the N Pen Start FluorPen program Connect N Pen device Setup Device ID Ctrl I Download measured data from the N Pen to your PC by c...

Page 32: ...flectance and algorithms for non destructive chlorophyll assessment in higher plant leaves Journal of Plant Physiology 2003 160 271 282 Klem K Prediction of spring barley nutrition state and grain qua...

Page 33: ...ses associated with the repair or installation of replacement parts at the customer s site The manufacturer repairs or replaces faulty instruments as quickly as possible the maximum time is one month...

Reviews: