GB
2.1 Maximum environment temperature
+ 50ºC
2.2 Water temperature
From 0ºC to + 50ºC.
2.3 Maximum working pressure allowed
2 bar. (possible water hammer must not be more than 3 Kg.)
2.4 Maximum input pressure
The input pressure when the pump is working against a closed valve must be lower than the
maximum permitted working pressure.
2.5 Minimum input pressure
Maximum suction 3 m.
Maximum autosuction 2 m.
See also the characteristics plate.
Protection: IP 55.
Isolation: Class F.
2.6 Electrical details
MAXI model pumps are of centrifugal type with a horizontal construction and auto-suction
capacity.
Their main application is to rotate the water in the swimming pool and they are normally in-
stalled before the filtering unit. The pump is designed to decant chlorine-disinfected swim-
ming pool water.
The MAXI pumps include a removable basket to filter small solids.
1
Applications
Carefully read the instructions before starting the installation process, which should be
in accordance with local standards.
2
Technical information
Voltage: 1 x 220 / 230 V 50 Hz
MAXI 15 M
MAXI 20 M
Voltage: 3 x 220 / 230 V 50 Hz
MAXI 15 T
MAXI 20 T
MAXI 30 T
MAXI 40 T
Instruction Manual for Series MAXI