PSH MAXI 15 M Instructions For Use And Maintenance Manual Download Page 2

Instruction Manual for Series MAXI

Prime the pump (if not risk of dry running). WAR-
RANTY LOSS!!!

Regularly  check  the  waterproofness!  (A  leak
through a mechanical seal can cause important
damages!)

Do  not  use  any  reduction  at  suction  and  drive
mouths

Starting up only with open valves

CORRECT! Prevent the entry of water through the
electrical cable

Pay attention on the cable position in order to prevent water seeping into the terminal box.

INCORRECT!

Daily cleaning of the prefilter basket.

In order to avoid mechanical seal blocking, turn

the shaft trough the motor fan before starting up
or after extended unuse!

Compulsory check by starting up and functioning of the pump:

Install the pump in a well ventilated room or protected from weather impacts.

Do not substitute the instruction manual enclosed!

Summary of Contents for MAXI 15 M

Page 1: ...serie MAXI Instructions for use and maintenance...

Page 2: ...entry of water through the electrical cable Pay attention on the cable position in order to prevent water seeping into the terminal box INCORRECT Daily cleaning of the prefilter basket In order to av...

Page 3: ...details MAXI model pumps are of centrifugal type with a horizontal construction and auto suction capacity Their main application is to rotate the water in the swimming pool and they are normally in st...

Page 4: ...ver on the top It must be possible to remove the transparent cover to take out the pre filter basket for cleaning The suction pipe must have at least the same diameter as the pump suction inlet diamet...

Page 5: ...rom the swimming pool edge Make sure that the electrical supply is turned off before removing the connection box cover or before any moving or disassembling of the pump The electrical connections must...

Page 6: ...ctly primed when the water is just below the transparent cover The arrows on the pump housing indicate the correct rotation In order to create maximum suction capacity when starting close the discharg...

Page 7: ...Check the pre filter basket Tighten thumb screws of the lid equally 5 The suction is too high The maximum height allowed is 3m 6 The sum of the load losses from the installation exceeds the pumping ca...

Page 8: ...Dimensions Type MAXI 15 M T MAXI 20 M T MAXI 30 T MAXI 40 T L 675 675 700 700 Dimensions...

Page 9: ...phase cable bolt 32 Terminal box gasket 38 Terminal box cover gasket 41 Nut capsule 43 Pump side motor seal 44 Fan side motor seal 47 Terminal plate washer 50 Drip washer 53 Filter pump housing washe...

Page 10: ...ew 37 Fan clamp 40 Complete press cable 44 Fan side motor seal 47 Terminal plate washer 49 Cable passage gasket 53 Filter pump housing washer 55 Impeller 57 Impellernut 58 Diffusser 61 Pump housing ga...

Reviews: