Step 10
In the event of an air leak, remove
the air chamber and replace the
gasket.
D A M P E N E R D I S A S S E M B L Y
Step 11
Disassembly of the regulator body
from the regulator adaptor plate
is needed only in the event of air
leakage.
Step 12
In the event of an air leak, remove
the regulator adaptor plate and
replace the O-ring.
Step 13
Using an O-ring pick, remove the
Glyd rings from air regulator body.
Step 14
The air regulator body has five
(5) grooves cut into the inside
diameter. There are three Glyd rings
installed in the 1, 3 and 5 positions.
It is important that these Glyd rings
be installed in the correct grooves
so that the Equalizer
®
functions
properly. Please refer to the drawing
for the correct location of the Glyd
rings.
5
3
1