WIL-10184-E-03
8
P8 Clamped Metal
SECTION 5
P8 METAL
RUBBER-FITTED
Ship Weights………….Aluminum 32 kg (70 lb)
Stainless Steel 51 kg (112 lb)
Cast Iron 47 kg (104 lb)
Alloy C 52 kg (114 lb)
Air Inlet……………………..……..13 mm (1/2")
Inlet…...…………………...…………51 mm (2")
Outlet………………...………………51 mm (2")
Suction Lift……………………6.9 m Dry (22.7’)
8.6 m Wet (28.4’)
Disp. per Stroke
1
……...…........2.6 L (0.70 gal)
Max. Flow Rate……………623 lpm (165 gpm)
Max. Size Solids…………………6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 386 lpm (102 gpm) against
a discharge head of 2.8 bar (40psig) requires 5.5
bar (80 psig) and 137Nm
3
/h (85 scfm) air
consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
P8 METAL
TPE-FITTED
Ship Weights………….Aluminum 32 kg (70 lb)
Stainless Steel 51 kg (112 lb)
Cast Iron 47 kg (104 lb)
Alloy C 52 kg (114 lb)
Air Inlet……………………..……..13 mm (1/2")
Inlet…...…………………...…………51 mm (2")
Outlet………………...………………51 mm (2")
Suction Lift……………………6.7 m Dry (22.1’)
8.6 m Wet (28.4’)
Disp. per Stroke
1
……...…........2.8 L (0.75 gal)
Max. Flow Rate……………630 lpm (166 gpm)
Max. Size Solids…………………6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 227 lpm (60 gpm) against
a discharge head of 3.4 bar (50 psig) requires
4.1 bar (60 psig) and 66 Nm
3
/h (41 scfm) air
consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
DIMENSIONAL DRAWING
PERFORMANCE