3.1.12 THERMOSTAT
The thermostat must be installed on an inside wall in a location where it is not
likely to be affected by the draft coming from an air outlet. It must be installed at
a minimum of 55 inches above the floor. The two thermostats on a combined
system must be installed at the same height. The Mini-Caddy wood Add-on
furnace’s thermostat must be positioned between 18°C et 21°C (65°F et 70°F) or
to a temperature slightly higher (2°C à 3°C) than the existing furnace. It controls
the opening or closing of the air intake of the wood Add-on furnace.
3.1.13 SAFETY PRECAUTION
CAUTION
THE OPERATION OF A GAS FURNACE MUST BE VERIFIED FOR
ACCEPTABLE OPERATION BEFORE AND AFTER INSTALLATION OF THE
MINI-CADDY ADD-ON APPLIANCE BY A GAS FITTER WHO IS
RECOGNIZED BY THE REGULATORY AUTHORITY.
CAUTION
DO NOT CONNECT TO ANY GAS FURNACE THAT HAS NOT BEEN
CERTIFIED INITIALLY AS COMPLYING WITH CGA STANDARD CAN/CGA-
2.3 OR ITS PRECEDENTS.
3.1.14 OPERATING INSTRUCTIONS
Operate the existing furnace periodically to ensure that it will operate
satisfactorily when needed.
On the wood furnaces, the thermostat controls the air inlet damper. When the
thermostat calls for heat, the damper opens and the combustion is stirred up.
When the furnace gets hot enough, the fan limit control activates the blower
motor at the speed selected for wood heating.
Summary of Contents for MINI-CADDY PF01301
Page 15: ...15 MINI CADDY ADD ON Installation Instructions MINI CADDY ADD ON PF01301 ...
Page 25: ...25 MINI CADDY ADD ON Example 1 Example 2 ...
Page 34: ...34 MINI CADDY WOOD ONLY Installation instructions for MINI CADDY WOOD ONLY PF01301 ...
Page 41: ...41 MINI CADDY WOOD ONLY 3 2 13 WIRING DIAGRAM ...
Page 43: ...43 MINI CADDY WOOD ELECTRIC Installation instructions for MINI CADDY WOOD ELECTRIC PF01301 ...
Page 48: ...48 MINI CADDY WOOD ELECTRIC 3 3 7 WIRING DIAGRAM ...