background image

Cop

yright ©2014 Goodman Manufacturing Co

mpany, L.P.

RT6612032

August 2014

This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures performed by an unqualified person.

Refer to Service Manual RS6612010 for installation, operation, and troubleshooting information.

Refer to the appropriate Parts Catalog for part number information.

Models listed on page 3.

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANUAL

AL

AL

AL

AL

TM

*CVC96/*MVC96

96% Gas Furnace Units

Summary of Contents for ACVC960403BNAA

Page 1: ...ty damage or personal injury due to improper service procedures performed by an unqualified person Refer to Service Manual RS6612010 for installation operation and troubleshooting information Refer to...

Page 2: ...G Goodman will not be responsible for any injury or property damage arising from improper service or service procedures If you install or perform service on this unit you assume responsibility for any...

Page 3: ...ay vary by jurisdiction Should questions arise contact your local EPA of fice WARNING WARNING To prevent the risk of property damage personal injury or death do not store combustible materi als or use...

Page 4: ...M VS ECM VS ECM Filter Size in Permanent 341 731 683 853 853 1 024 Disposable 171 366 341 427 427 512 Electrical Data Min Circuit Ampacity 7 8 7 8 7 8 10 6 14 4 14 4 Max Overcurrent Device amps 15 15...

Page 5: ...n Permanent 488 512 853 711 1 024 Disposable 244 256 427 356 512 Electrical Data Min Circuit Ampacity 7 8 7 8 10 6 14 4 14 4 Max Overcurrent Device amps 15 15 15 20 20 Shipping Weight lbs Natural Gas...

Page 6: ...1 26 23 UNFOLDED FLANGE S 22 FOLDED FLANGE S D FOLDED FLANGE S E UNFOLDED FLANGE S AIR DISCHARGE SIDE CUT OUT SIDE CUT OU T AIR DISCHARG E LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW CONDENSATE DRAI N...

Page 7: ...LY LOCATION HIGH VOLTAG E ELECTRICAL OUTLET STANDARD DRAIN TRAP CONNECTION PVC LEFT SIDE EXTERIOR DRAIN TRAP HOLE S ALTERNATE GAS SUPPLY LOCATIO N ALTERNATE VENT FLUE LOCATION HIGH VOLTAGE ELECTRICAL...

Page 8: ...83 Plus 10 744 631 48 MVC960603BNA Cooling Speed 1 8 w c ESP MVC960603BNA Heating Speed 1 5 w c ESP Rise Range 20 50 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Low Stage CFM R...

Page 9: ...353 901 Plus 10 1 536 1 169 46 MVC960804CNA Cooling Speed 1 8 w c ESP MVC960804CNA Heating Speed 1 5 w c ESP Rise Range 25 55 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Low St...

Page 10: ...10 1 910 1 385 Plus 10 2 153 1 494 41 MVC961205DNA Cooling Speed 1 8 w c ESP MVC961205DNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CF...

Page 11: ...314 932 27 Plus 10 1 328 939 Plus 10 1 376 977 26 CVC960603BNA Cooling Speeds 1 8 w c ESP CVC960603BNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust...

Page 12: ...10 1 375 961 52 Minus 5 1 401 941 Minus 5 1 452 1 015 49 Normal 1 475 991 Normal 1 528 1 068 47 Plus 5 1 549 1 041 Plus 5 1 604 1 121 n a Plus 10 1 623 1 090 Plus 10 1 681 1 175 n a CVC961005CNA Cool...

Page 13: ...897 567 Plus 5 1 831 1 348 58 Plus 10 939 594 Plus 10 1 918 1 412 56 B Minus 10 1 011 783 B Minus 10 1 644 1 179 65 Minus 5 1 067 827 Minus 5 1 736 1 245 61 Normal 1 123 870 Normal 1 827 1 310 58 Plus...

Page 14: ...7 AMPS LIMIT CONTROL AUXILIARY AUTO RESET PK WARNING DISCONNECT TRANSFORMER 40 VA PU GY N NO 3 BR 4 UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N E C AND LOCAL CODES COLOR CODES 1 E SWITCH PRESS...