WIL-12630-E-04
Wilden
®
11
PERFORMANCE
PS15 SANIFLO™ HS
FULL-STROKE
PTFE-
FITTED
Ship Weight ......................... 98 kg (216 lb)
Air Inlet.................................... 19 mm (3/4")
Inlet ......................................... 76 mm (3")
Outlet ......................................... 76 mm (3")
Suction Lift ...................... 4.0 m Dry (13.1')
9.0 m Wet (29.5')
Disp. Per Stroke
1
..................... 2.3 L (0.62 gal)
Max. Flow Rate ............ 749 lpm (198 gpm)
Max. Size Solids ...........................................
Mushroom Valve 9.5 mm (3/8")
Ball Valve 19.1 mm (3/4")
Flap Valve 60.3 mm (2-3/8")
Surface Finish ............... Ra 0.08 mm (32 m-in)
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.0 bar (30 psig) head pressure.
Example:
To pump 284 lpm (75 gpm)
against a discharge head of 3.5 bar
(50 psig) requires 5.6 bar (80 psig) and
140 Nm
3
/h (50 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.
PS15 SANIFLO™ HS
FULL-STROKE
INTEGRAL PISTON
DIAPHRAGM-FITTED
Ship Weight ......................... 98 kg (216 lb)
Air Inlet.................................... 19 mm (3/4")
Inlet ......................................... 76 mm (3")
Outlet ......................................... 76 mm (3")
Suction Lift ...................... 3.8 m Dry (12.5')
9.0 m Wet (29.5')
Disp. Per Stroke
1
..................... 2.5 L (0.65 gal)
Max. Flow Rate ............ 802 lpm (212 gpm)
Max. Size Solids ...........................................
Mushroom Valve 9.5 mm (3/8")
Ball Valve 19.1 mm (3/4")
Flap Valve 60.3 mm (2-3/8")
Surface Finish ............... Ra 0.08 mm (32 m-in)
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure against
a 2.0 bar (30 psig) head pressure.
Example:
To pump 628 lpm (166 gpm)
against a discharge head of 1.4 bar
(20 psig) requires 7.0 bar (100 psig)
and 138 Nm
3
/h (81 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.