WIL-12630-E-04
Wilden
®
10
PERFORMANCE
PS15 SANIFLO™ HS
RUBBER-FITTED
Ship Weight ....................... 98 kg (216 lb)
Air Inlet.................................. 19 mm (3/4")
Inlet ....................................... 76 mm (3")
Outlet ....................................... 76 mm (3")
Suction Lift ................... 4.4 m Dry (14.5')
9.0 m Wet (29.5')
Disp. Per Stroke
1
.................. 2.7 L (0.72 gal)
Max. Flow Rate .......... 844 lpm (223 gpm)
Max. Size Solids ........................................
Mushroom Valve 9.5 mm (3/8")
Ball Valve 19.1 mm (3/4")
Flap Valve 60.3 mm (2-3/8")
Surface Finish ............ Ra 0.08 mm (32 m-in)
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.0 bar (30 psig) head pressure.
Example:
To pump 503 lpm (133 gpm)
against a discharge head of 2.8 bar
(40 psig) requires 7.0 bar (100 psig)
and 140 Nm
3
/h (82 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.
PS15 SANIFLO™ HS
EZ-INSTALL TPE-FITTED
Ship Weight ......................... 98 kg (216 lb)
Air Inlet.................................... 19 mm (3/4")
Inlet ......................................... 76 mm (3")
Outlet ......................................... 76 mm (3")
Suction Lift ...................... 3.1 m Dry (10.2')
9.0 m Wet (29.5')
Disp. Per Stroke
1
..................... 2.5 L (0.67 gal)
Max. Flow Rate ............ 844 lpm (223 gpm)
Max. Size Solids ...........................................
Mushroom Valve 9.5 mm (3/8")
Ball Valve 19.1 mm (3/4")
Flap Valve 60.3 mm (2-3/8")
Surface Finish ............... Ra 0.08 mm (32 m-in)
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.0 bar (30 psig) head pressure.
Example:
To pump 416 lpm (110 gpm)
against a discharge head of 3.6 bar
(52 psig) requires 7.0 bar (100 psig)
and 126 Nm
3
/h (74 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Section 5
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.