WIL-19230-E-01
Wilden
®
11
Edge Device
The batteries within the Edge Device are expected
to last up to 1 year. The Edge Device requires (2)
AA batteries. When the batteries need to be
replaced, follow Steps 9 through 11 of the
installation process:
1.
Remove the rubber seal from the Edge
Device
2.
Unscrew the top of the Edge Device by
hand to remove the cap
3.
Take the old batteries out, insert the
(2) new AA batteries
4.
A light will flash blue when powered.
Reinstall the Edge Device cap and
rubber seal
Edge Device LED Light Indicators
The Edge Device has two LED Light indicators. One
to indicate its on/off and paired/not paired status
and one to indicate a warning or fault.
LED Light #1
On/Off – Edge Device has Power
Blinks every 5 seconds
Single Blink – Edge Device is Paired
Double Blink – Edge Device is Not Paired
LED Light #2
Mirrors Indicators on Pump Dashboard
Single Blink – Warning
Double Blink – Fault
Leak Detection
In the event that a leak is detected via the Leak
Detection Sensor, the product could potentially
contaminate the float switch and the float switch
may need to be replaced. To replace the Leak
Detection Sensor float switch, take the following
actions:
1.
Disconnect the Leak Detection Sensor
from the J-Box
2.
Remove the two screws from the top of
the Leak Detection Sensor and remove
the cap, the float switch will be attached
to the cap
3.
Insert the replacement float switch and
cap and secure with the screws
4.
If needed, drain and clean the Leak
Detection Sensor by unscrewing the
screws on the ears of the Leak
Detection Sensor and gently pulling
down on the Detection well.
MAINTENANCE
Section 5
Summary of Contents for Wilden SafeGuard
Page 15: ...WIL 19230 E 01 Wilden Notes ...