WIL-10187-E-03
Wilden
®
8
PERFORMANCE
P8 PLASTIC
RUBBER
-FITTED
Ship Weight ....... Polypropylene 34 kg (75 lb)
PVDF 43 kg (95 lb)
Air Inlet ..................................... 13 mm (1/2")
Inlet. .......................................... 51 mm (2")
Outlet ........................................... 51 mm (2")
Suction Lift .......................... 7.4m Dry (24.4')
8.6 m Wet (28.4')
Disp. Per Stroke
1
...................... 2.8 L (0.73 gal)
Max. Flow Rate ............. 591 lpm (156 gpm)
Max. Size Solids ...................... 6.4 mm (1/4")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure against
a 2.1 bar (30 psig) head pressure.
Example:
To pump 379 lpm (100 gpm)
against a discharge head of 2.1 bar
(30 psig) requires 4.1 bar (60 psig) and
104 Nm
3
/h (66 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.
P8 PLASTIC
TPE
-FITTED
Ship Weight ....... Polypropylene 34 kg (75 lb)
PVDF 43 kg (95 lb)
Air Inlet ..................................... 13 mm (1/2")
Inlet. .......................................... 51 mm (2")
Outlet ........................................... 51 mm (2")
Suction Lift ......................... 5.9 m Dry (19.3')
8.6 m Wet (28.4')
Disp. Per Stroke
1
...................... 2.8 L (0.73 gal)
Max. Flow Rate ............. 583 lpm (154 gpm)
Max. Size Solids ...................... 6.4 mm (1/4")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure against
a 2.1 bar (30 psig)head pressure.
Example:
To pump 371 lpm (98 gpm)
against a discharge head of 2.1 bar
(30 psig) requires 4.1 bar (60 psig)
and 107 Nm
3
/h (68 scfm) air consumption.)
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.
Section 5
Summary of Contents for WILDEN PRO-FLO P8
Page 27: ...WIL 10187 E 03 Wilden Notes...