background image

20/28

NT 1001-P00 02 19 Pumps Micro C  e

5.1 Necessary tools

13 & 11 Open-end spanners 

• 32 Open-end spanner or monkey spanner

• Wrench for 6 flats with 5” groove

• 2 screwdrivers

Makeup torques :

• M6 :      5 Nm

• M8 :     13 Nm

• M14 :   25 Nm

5.2 Disassembly

• Disconnect the pump from the discharge pipe.

Unscrew the 4 screws 

415

.

Before any dismantling, make sure that the pump has
been drained and take the necessary measures to
avoid starting-up. No start-up, even accidental, must be
allowed.

415

5. MAINTENANCE

Pump greased for life with Food synthetic grease

CAUTION

THE PUMP LUBRICANT IS VERY SLIPPERY
AND MAY CAUSE SERIOUS INJURY. ANY
SPILLS MUST BE CLEANED UP.

Slippery lubricant.

Spills should be

cleaned up.

WARNING

BE CAREFUL WITH THE WEIGHT OF THE
PARTS WHEN THEY ARE BEING REMOVED.

The weight ot the parts

can be dangerous and

may provoke bodily

injuries or material 

damages.

WARNING

TAKE ALL NECESSARY MEASURES TO
RENDER ANY START-UP, EVEN ACCI-
DENTAL, OF THE PUMP DURING THE
WORK IMPOSSIBLE.

Any unforeseen start-up 

can cause serious

injuries or important 

material damages.

WARNING

FAILURE TO RELIEVE THE SYSTEM
PRESSURE PRIOR TO PERFORMING
ANY WORK ON THE PUMP OR THE
INSTALLATION CAN CAUSE PERSONAL
INJURY OR PROPERTY DAMAGE.

Hazardous pressure 

can cause 

personal injury 

or property damage.

WARNING

DISCONNECTING THE FLUID OR PRES-
SURE CONTAINMENT COMPONENTS
DURING PUMP OPERATION CAN CAUSE
SERIOUS PERSONAL INJURY, DEATH OR
MAJOR PROPERTY DAMAGE.

Hazardous pressure 

can cause 

personal injury 

or property damage.

WARNING

IF PUMPING HAZARDOUS OR TOXIC
FLUIDS, THE SYSTEM MUST BE
FLUSHED PRIOR TO PERFORMING ANY
SERVICE OPERATION.

Hazardous or toxic

fluids can cause

serious injury.

Summary of Contents for Mouvex Micro C 125

Page 1: ...ne des Isles F 89000 AUXERRE FRANCE Tel 33 0 3 86 49 86 30 Fax 33 0 3 86 49 87 17 contact mouvex psgdover com www mouvex com WARRANTY MICRO C Series pumps are covered 24 months by warranty within the...

Page 2: ...l pressure for example pressure difference between equipment suction and discharge Unit with suffix a Absolute pressure Unit with suffix g Gauge pressure given regarding to atmospheric pressure 101325...

Page 3: ...02 19 Pumps Micro C e 1 OVERALL DIMENSIONS Weight 8 kg M6 Max depth 12 0 472 S c r e w p a s s a g e 4 0 1 5 7 5 Pump plate 4 x 6 2 0 244 on 100 3 937 Connection BSP or NPT 1 2 Motor flange CEI FT FF...

Page 4: ...02 19 Pumps Micro C e 1 OVERALL DIMENSIONS continued Weight 8 kg M6 Max depth 12 0 472 S c r e w p a s s a g e 4 0 1 5 7 5 Pump plate DIN 11851 DN20 Motor flange CEI FT FF 100 1 4 BSP Event 4 x 6 2 0...

Page 5: ...NT 1001 P00 02 19 Pumps Micro C e 1 OVERALL DIMENSIONS continued CONNECTION CLAMP ISO 2852 D25 Screw passage 40 1 575 Pump plate M6 Max depth 12 0 472 1 4 BSP Event 4 x 6 2 0 244 on 100 3 937 Weight...

Page 6: ...P00 02 19 Pumps Micro C e 1 OVERALL DIMENSIONS continued Weight 8 kg M6 Max depth 12 0 472 Screw passage 40 1 575 Pump plate CLAMP DIN 32676 DN20 Motor flange CEI FT FF 100 1 4 BSP Event 4 x 6 2 0 244...

Page 7: ...02 19 Pumps Micro C e 1 OVERALL DIMENSIONS continued Weight 8 kg M6 Max depth 12 0 472 S c r e w p a s s a g e 4 0 1 5 7 5 Pump plate SMS 1145 D25 Motor flange CEI FT FF 100 1 4 BSP Event 4 x 6 2 0 2...

Page 8: ...2 19 Pumps Micro C e 1 OVERALL DIMENSIONS continued Weight 8 kg M6 Max depth 12 0 472 Screw passage 40 1 575 Pump plate CLAMP ASME BPE 2009 D25 4 Motor flange CEI FT FF 100 1 4 BSP Event B B 4 x 6 2 0...

Page 9: ...9 28 NT 1001 P00 02 19 Pumps Micro C e 1 OVERALL DIMENSIONS continued Support bracket CAUTION This variant involves limitations on ports orientation inlet tube port downward forbidden...

Page 10: ...10 28 NT 1001 P00 02 19 Pumps Micro C e 1 OVERALL DIMENSIONS continued Motor flange NEMA 143 S c r e w p a s s a g e 4 0 1 5 7 5 M6 Max depth 12 0 472...

Page 11: ...11 28 NT 1001 P00 02 19 Pumps Micro C e 1 OVERALL DIMENSIONS continued NEMA H Flange adaptation M6 Max depth 12 0 472 Screw passage 40 1 575 4 x 3 8 UNC 0 244 over R74 6 R2 937...

Page 12: ...ny time to ask for the information you require 2 1 2 Pipe Suction pipe length Length should be as short as possible Suction pipe diameter Diameter must be at least equal to pump port diameter and even...

Page 13: ...ust be heated before fluid contained in the pump Also check that a heated pump is not iso lated by closed valves The Micro C pump is a self priming volumetric PD pump Therefore the pump must not run o...

Page 14: ...riven pump unit without deformation if it is made of concrete it must comply with the BAEL 91 standard If the unit is fastened using securing lugs or bolts it must be carefully wedged to avoid deformi...

Page 15: ...ELECTIC MOTORS Check the compatibility of the instructions on the motor with the supply voltage Follow the wiring diagram use wiring that is appropriate for the power and be particularly careful abou...

Page 16: ...ced by its conditions of use Cavitation and pumping products with high gas contents generally increases the sound level Under the following pumping conditions excluding cavitation discharge pressure s...

Page 17: ...avoid any clogging or untimely drying Non compliance with these instructions will lead to rapid deterioration of the cylinder piston pair 4 2 CIP circuit recommended In all cases the pressure at the p...

Page 18: ...ld be noted that during cleaning the Micro C pump will generally be acting on a product with few lubricating properties This will contribute towards wear of the pump The CIP centrifuge pump must never...

Page 19: ...ith an acid solution Typically this is 2 5 nitric acid at room temperature 10 to 15 minute cycle This wash helps to dissolve and evacuate proteins and inorganic salts in particular 5 Rinsing with clea...

Page 20: ...WHENTHEYAREBEINGREMOVED The weight ot the parts can be dangerous and may provoke bodily injuries or material damages WARNING TAKE ALL NECESSARY MEASURES TO RENDER ANY START UP EVEN ACCI DENTAL OF THE...

Page 21: ...1 Remove seal 306 from piston 301 Remove cylinder 201 and seal 212 Remove manifold 100 and seal 113 It is important to keep a good grip on the cylinder as you take the front cover off Its rotation cou...

Page 22: ...paper No 320 grain or equivalent taking care of not scratching any other surface around Piston must then look as follows Do not retouch any other surface of the piston by any mean as it can degrade pu...

Page 23: ...er 201 Also check that pin 311 on the piston faces groove on transmission hub 596 Give a small sideways push to the piston in order to centre it and engage it in the cylinder then push it tight to the...

Page 24: ...ld as explained in the DISASSEMBLY paragraph Next unscrew the 4 screws 144 and the 4 washers 143 and uncouple trunk 780 from the transmission 596 CAUTION BE CAREFUL NOT TO KNOCK OR SCRATCH THE BELLOWS...

Page 25: ...aces of the pump e g shafts couplings etc should be covered in some form of anti corrosion protection If pump storage lasted more than the life of the grease the transmission should be replaced in tim...

Page 26: ...sult in pump noise The cause could be 3 1 1 a the suction lift is too high reduce it by taking the pump down closer to the level of the liquid b the dynamic suction losses are too high the inlet pipin...

Page 27: ...h or has become too high due to excessive head losses following clog ging of the piping or filter a change of viscosity of the liquid etc 5 3 an increase of the vapour pressure with a rise of temperat...

Page 28: ...gen bezogen auf mechanische und elektrische Risiken die f r rotierende Maschinen gelten NF EN 809 2009 NF EN 1672 2 2009 NF EN ISO 13857 2008 NF EN 12162 2009 ATEX Richtlinie 2014 34 EU 26 Feb 2014 wi...