background image

2/7

NT 1005-C00 09 18 Pump AF TM H  e

INSTALLATION

Rotation

MOUVEX pump is reversible. Suction and discharge ends
are bound to rotation as indicated on plate fixed to pump.

Bypass orientation

Operation

Acting as a relief valve, the bypass protects pump and auxilia-
ry equipment from damage due to excessive pressures that
may be built up when the pump runs against some obstruction
in the discharge piping.

When discharge pressure reaches the pressure limit for which
the bypass is set, valve 

803

opens and thus allows the liquid to

be circulated from the discharge side back to the suction side.

Orientation

The single bypass protects the pump in one direction of rota-
tion only.

Therefore make sure it is rightly installed by checking that
bypass cap is on the suction side and reverse bypass if
necessary.

Reversing

To reverse bypass, remove nuts 

814

and rotate bypass body

by 180°.

Check gaskets 

877

.

Tighten nuts 

814

taking care to keep bypass on end.

Motor protection

As the bypass protects the pump only, electric motors should
be equipped with their own protection device.

D : Bypass
E : Bypass cap
F : Fixing stud and nut
G : Bearing nipple

Summary of Contents for Mouvex AF TM H Series

Page 1: ...tor Z I La Plaine des Isles F 89000 AUXERRE FRANCE Tel 33 0 3 86 49 86 30 Fax 33 0 3 86 49 87 17 contact mouvex com www mouvex com WARRANTY TM Series pumps are covered 24 months by warranty within the limits mentioned in our General Sales Conditions In case of a use other than that mentioned in the Instructions manual and without preliminary agreement of MOUVEX warranty will be canceled ...

Page 2: ... the bypass is set valve 803 opens and thus allows the liquid to be circulated from the discharge side back to the suction side Orientation The single bypass protects the pump in one direction of rota tion only Therefore make sure it is rightly installed by checking that bypass cap is on the suction side and reverse bypass if necessary Reversing To reverse bypass remove nuts 814 and rotate bypass ...

Page 3: ...orget to replace cap 833 With the bypass spring it is possible to set the pressure bet ween 1 7 and 6 5 bar valve closed Delivery adjustement When the pump does not deliver the proper flow rate the trouble may come from bypass spring not being adjusted at the correct pressure setting After making sure that the rotation speed is correct tighten adjusting nut 834 Should the spring be completely tigh...

Page 4: ...nt ling Before assembling check that spring 504 of piston bea ring 503 and piston backsprings 310 has not weakened To reassemble shaft seal bearing and shaft Refer to SHAFT SEAL To reassemble piston and to close the pump After remounting in place the seal end plate 403 engage the piston 301 on the shaft 501 Insert the piston 301 in the cylinder 201 by making bend the spring 504 of piston bearing 5...

Page 5: ...aft seal remove snap ring 704 drive out shaft from bearing by tap ping on shaft end and remove the set 701 731 733 703 remove the set 604 605 then all MONOSIR block 601 MONOSIR block 601 must not be dissociated Reassembly Check rings 707 605 and rubber faces of block 601 Check that sealing faces of 604 and block 601 are flat and mirror smooth Replace all parts on shaft in the reverse order and ins...

Page 6: ... of the grease this one should be replaced in time to prevent an excessive degradation of its qualities The best storage conditions are inside a building that meets the conditions set out above If inside storage is not possible the materials should be covered to prevent direct exposure to sun and bad wea ther This protection should also prevent condensation The pump should be turned a few revoluti...

Page 7: ...gen bezogen auf mechanische und elektrische Risiken die für rotierende Maschinen gelten NF EN 809 2009 NF EN 1672 2 2009 NF EN ISO 13857 2008 NF EN 12162 2009 ATEX Richtlinie 2014 34 EU 26 Feb 2014 wie umgesetzt im nationalen Recht in Bezug auf Ausrüstungen für den Einsatz in explosionsgefährdeter Atmosphäre Die Konformität hat Geltung durch Anwendung folgender Normen NF EN 1127 1 1997 NF EN 13463...

Reviews: