PSC ProMix 6 Operational Manual Download Page 7

6

Input Panel View

Pre-Amplifiers

The inputs of the PSC ProMix 6 are all female XLR connectors and the input
circuitry is balanced.  Careful attention was given to RF immunity for the input
circuitry to help eliminate RF problems in the field.  The XLR connectors are
wired as follows:  

Pin 1 = Ground,  Pin 2 = High

 (Audio in Phase), 

Pin 3 Low

(Audio out of Phase)

Gain Settings

The six input channels of the PSC  ProMix 6 use pre-amplifiers that are designed
for real-world ease of use.  These pre-amplifiers have 3 basic gain settings.
These gain settings are labeled: 

C

 (Condenser Microphone) L (Line Level Input)

and

  D

 (Dynamic Microphone) Using these 3 settings makes for easy and fast

setups in the field.  You must simply select the gain setting that best matches
your input signal and you are done.  Typically, Condenser microphones (powered
microphones) have a higher output level than that of a dynamic microphone.  To
use a condenser microphone, just set the input gain setting switch to “

C

”.  To use

a dynamic microphone, set the input gain switch to “D”  When using line level
sources, set the input gain setting switch to “

L

”  When using most wireless

microphone receivers, set the input gain setting switch to “

C

”.

Microphone Powering

The PSC  ProMix 6 audio mixer is equipped with 48PH microphone power.  Each
of the six input channels has a separate switch to enable the 48PH microphone
power for that individual channel.  These switches are labeled “

D

” and “

48

”.  In

the “D” position, there is no microphone power being applied to that XLR input.

Summary of Contents for ProMix 6

Page 1: ...ProMix 6 Audio Mixer Operational Manual For PCB Version 1 7 Copyright 2007...

Page 2: ...6 Pre Amplifiers 6 Gain Settings 6 Microphone Powering 7 Dedicated Line Outputs 7 Headphone Outputs 7 Front Panel View 8 Channel Fader 8 High Pass Filters 8 Channel Assignment Switch 8 Pre Fade Listen...

Page 3: ...If you have any questions comments or suggestions about this mixer or any other PSC product please do not hesitate to call or e mail us Additionally we invite you to share your suggestions for new pr...

Page 4: ...evision Production HEARING SAFETY WARNINGS Please be sure that you have read this entire manual before operating this mixer While special attention has been given to your safety and hearing protection...

Page 5: ...that are the result of many hours spent testing and tweaking the input circuitry We believe that you will find these pre amplifiers to be very quiet In addition the ProMix 6 also uses our exclusive s...

Page 6: ...5...

Page 7: ...r easy and fast setups in the field You must simply select the gain setting that best matches your input signal and you are done Typically Condenser microphones powered microphones have a higher outpu...

Page 8: ...from the corresponding input They feature a line output jack operating at a nominal level of 10dBv These six outputs are un balanced and are wired as follows Tip audio signal Ring unused Sleeve Groun...

Page 9: ...busses When set to R the signal is routed to just the right output bus Pre Fade Listen Switch Each input channel of the PSC ProMix 6 is equipped with a Pre fade Listen switch These push button switch...

Page 10: ...tteries useful life is nearly over and you should stop and change your batteries soon Actual remaining battery life is dependent upon use of the mixer number of powered condenser microphones being use...

Page 11: ...uations split tracks are used and thus the S setting on the limiter switch is employed Headphone Selection On the right side of the front panel there is a rotary switch that is used to control what yo...

Page 12: ...the nominal audio output level is 50dBv These audio signal levels correspond to the following 0dBv corresponds to professional line level 10dBv corresponds to consumer line level and 50dBv correspond...

Page 13: ...wer supply should also be rated to provide a minimum of 300mA for proper operation Internally the mixer is protected against reversed polarity If you incorrectly provide the external power connector w...

Page 14: ...and some semi professional cameras XLR Inputs To interface your new ProMix 6 to one or two professional video cameras is easily done The most simple and convenient way is to use a PSC betasnake cable...

Page 15: ...hen plug in a cable with a stereo connector into this jack The other end of the cable should have a 3 5mm stereo mini plug to be able to plug it into your camera DEVICE DEVICE INPUT CONECTOR PROMIX 6...

Page 16: ...we at PSC fully support this plan Several other counties are considering adopting similar standards at the time this manual was written as is the State of California All Professional Sound Corporation...

Page 17: ...AA Alkaline Cells Meters LED Peak Reading Multi Colored Slate Microphone Electrete Condenser Reference Osc 440Hz Frequency Resp 20Hz to 20Khz 0 5 dB Distortion 0 08 THD Signal to Noise 128db EIN Cros...

Page 18: ...6 REPONSIBLE PARTY Professional Sound Corp 28085 Smyth Drive Valencia CA 91355 USA CONTACT PERSON Ronald Meyer 661 295 9395 TYPE OF PRODUCT Audio Mixer MANUFACTURER Professional Sound Corp 28085 Smyth...

Reviews: