background image

POWERMAX ULTRA USE: 

 
The PSC PowerMax Ultra is designed for use in powering your entire digital 
audio recording package.  The PowerMax Ultra’s twelve (12), 4-pin female XLR 
output connectors provide all of the various output voltages at all times when the 
PowerMax Ultra is switched on.  Thus all power cables wired for use between the 
PowerMax Ultra and your equipment must be wired correctly and professionally.   
 
Anytime the PowerMax Ultra is plugged in and the AC power switch in “ON” its 
battery charger is turned on.  Thus your batteries may be charged without the 
PowerMax Ultra’s front panel electronics being turned on.  By pressing the round, 
RED, “ON” button, the PowerMax Ultra will turn on and begin to supply all of the 
various output voltages to your equipment.  If the PowerMax Ultra is connected 
to a battery, but not plugged into AC, all of the power will come from the battery.  
If the battery is discharged below a safe point, the PowerMax Ultra will not stay 
on when the “ON” button is pressed.  If the battery level is good, the PowerMax 
Ultra will latch on.  When the batteries are discharged to the point where the 
battery meter is readying empty, the PowerMax Ultra will automatically shut itself 
off.  

You can also shut off the PowerMax Ultra at any time by simply 

pressing the GREEN, “OFF” button for approximately 7 seconds.

    This 

“delayed” off function was designed into the PowerMax Ultra to prevent 
accidental shut off of your entire sound package should the “off” button be 
accidentally hit. You can also operate the PowerMax Ultra without batteries 
connected by simply plugging the PowerMax Ultra into AC and pressing the “ON” 
button.  The PowerMax Ultra will output all of the various voltages and supply up 
to approximately 450 watts of total output power when connected to AC only. 
 
 

OPERATING VOLTAGE: (100Vac to 240Vac or 127 to 370Vdc) 
 

The PSC PowerMax Ultra has a “universal” input voltage and can even be 
operated from high voltage DC current.  This design was chosen to facilitate the 
PowerMax Ultra operating worldwide with having to be adjusted.  Simply plug it 
into a properly wired outlet and you are ready to go. 
 
 

AC LINE SAFETY: 
 

Electrical safety codes require that electrical equipment be properly grounded for 
operator safety.  Many electrical outlets have been miss-wired with hot and 
neutrals reversed as well as having missing grounds.   This is especially true on 
film sets were all power lines are portable and neutrals get kicked out time and 
time again.  For your own safety and for the good of your equipment, you should 
test any AC line before connecting to it.  This can be done by using a small, low 
cost line checker available at most hardware stores.  These checkers look like an 

Summary of Contents for PowerMax Ultra

Page 1: ...PowerMax Ultra Power Distribution Platform Operation Manual Version 1 1 Copyright 2007 Professional Sound Corporation Printed in the U S A...

Page 2: ...ackage Its rugged design allows for complete confidence that you will have uninterrupted power throughout your recording sessions PLEASE BE SURE THAT YOU HAVE READ AND UNDERSTOOD THIS ENTIRE OPERATION...

Page 3: ...pped Polyfuse overload condition CHARGING The PSC PowerMax Ultra contains two built in chargers designed to charge up to two external Sealed Lead Acid SLA batteries That means you can connect either o...

Page 4: ...weekend etc The battery meter is also color coded from green to red as it falls from FULL towards EMPTY When the last red LED turns off so does the PowerMax Ultra PowerMax Ultra Battery Fuel Gauge sh...

Page 5: ...tery your battery only run time may be anywhere from 2 to 5 hours depending upon your equipment s power requirements We highly recommend that you use Pelican case batteries that are equipped with Neut...

Page 6: ...re only rated for use at up to 9 amps of current As the Powermax Ultra can charge at up to 15 amps per battery connection the use of Speakon connectors is highly recommended Dual Charger Single Large...

Page 7: ...the longest run time on batteries only and is recommended for equipment packages with very high current requirements and or for applications that require very long run times on batteries only No AC av...

Page 8: ...t any time by simply pressing the GREEN OFF button for approximately 7 seconds This delayed off function was designed into the PowerMax Ultra to prevent accidental shut off of your entire sound packag...

Page 9: ...om Green to Red then that particular polyfuse has been tripped Because there are individual LEDs monitoring the individual outputs you can easily find out which output has the problem For example the...

Page 10: ...pated for proper operation of the PowerMax Ultra Because of this the PowerMax Ultra is equipped with two low noise Panasonic fans These fans where chosen because of their efficient air moving abilitie...

Page 11: ...ckly recharge most batteries during breaks in filming lunch breaks wardrobe changes etc EQUIPMENT POWER CABLES PSC recommends that you use only two conductor unshielded 16AWG power cable for power dis...

Page 12: ...ULTRA SOME SMALL VIDEO MONITORS NOT ALL CHECK YOUR MANUAL 4P MALE XLR COAXIAL POWER PLUG PIN 1 OUTER RING PIN 2 CENTER PIN BATTERY POWER CABLES The cables used to connect the batteries to your PSC Pow...

Page 13: ...will help prevent inadvertently connecting the cables to the wrong piece of equipment We cannot stress enough the importance of good quality power cables and careful connections Poorly constructed and...

Page 14: ...CONTACT OR GROUNDING OWNERSHIP AND OR USE OF THE PSC POWERMAX ULTRA CONSTITUTES AGREEMENT WITH THESE TERMS SPECIFICATIONS Size 17 25 x 13 x 3 00 43 8cm x 33cm x 7 6cm Weight 12Lbs 5 5Kg Input Power 1...

Page 15: ...a RESPONSIBLE PARTY Professional Sound Corp 28085 Smyth Drive Valencia CA 91355 USA CONTACT PERSON Ronald Meyer 661 295 9395 TYPE OF PRODUCT Power Supply MANUFACTURER Professional Sound Corp 28085 Smy...