more than 375 square inches of heat dissipating surface.   This heat sink should be kept clean 
and dust-free during use.  The PSC Power Star LiFE does not use a fan for cooling.  If the heat 
sink becomes covered with dust, it will not properly function and you may cause damage to 
your device.  PSC recommends that you blow off the heat sink area with compressed air from 
time to time to keep the heat sink clean.   You must leave open space above and to the sides of 
the PSC Power Star LiFE for proper cooling to take place.  A minimum of 1 rack space (1.75”) 
should be left open above the unit for cooling purposes.  Likewise, this product should not be 
used in fully enclosed rack case or other enclosures that limit air flow.  Failure to provide proper 
ventilation can and will damage the unit and will void your warranty. 

 

Close up view of the custom made, gold anodized, PSC aluminum heat sink extrusion 

 

DC CONNECTIONS:   There are ten (10) XLR female DC output connectors located on the front 
panel of the PSC Power Star LiFE.  The first two (2) XLRs located to left hand side of the unit are 
rated for 8 Amps of output current.  The remaining eight (8) output connectors are all rated for 
3.5 Amps of output current.   Each connector is individually Poly Fuse protected and monitored 
via the adjacent LEDs.   If the connector is working properly, the GREEN LED will be lit.   If the 
Poly Fuse has been tripped (short circuit in your cable or equipment) the GREEN LED will turn 
off and the YELLOW LED will turn on indicating a fault condition.   Under normal conditions, you 
should never see any YELLOW LEDs.   If you see a YELLOW LED, there is a problem and you 
should investigate the cable and device connected  to that particular output connector 
immediately.   If you ever have any questions about this, please do not hesitate to call PSC and 

Summary of Contents for POWER STAR LiFE

Page 1: ...PSC POWER STAR LiFETM Operation Manual Version 3 0 Copyright 2012 Professional Sound Corp 28085 Smyth Drive Valencia CA 91355 USA CE RoHS Printed in the U S A...

Page 2: ...TO BLOCK THE COOLING HEAT SINK AND OTHER VENT OPENINGS ALWAYS ALLOW AT LEAST A ONE RACK SPACE AIR GAP ABOVE THE COOLING HEAT SINK OPENINGS AND AROUND ALL VENT OPENINGS ALL AUXILARY EQUIPMENT SHOULD B...

Page 3: ...v whats_new_batteries html Additional information concerning Larger Batteries that applies to this product can be found here http safetravel dot gov larger_batt html Never ship your PSC Power Star LiF...

Page 4: ...the AC cord socket is a built fuse holder that holds the AC protection fuse This unit uses a 250v 15 Amp slow blow 5 x 20mm fuse A spare fuse is included inside the fuse holder drawer There are no oth...

Page 5: ...warranty Close up view of the custom made gold anodized PSC aluminum heat sink extrusion DC CONNECTIONS There are ten 10 XLR female DC output connectors located on the front panel of the PSC Power Sta...

Page 6: ...ore the unit will shut off This time delay function serves to keep you from accidentally shutting down the PSC Power Star Life unexpectedly while working RED and GREEN Power On and OFF switches FUEL G...

Page 7: ...indicating AC power is connected RESET BUTTON Located just above the AC LED is a small red push button switch located within a guard ring This switch is used to manually reset the LiFE battery protec...

Page 8: ...work This manual reset button is a PSC exclusive feature RESET switch located above the AC LED REMOTE CONTROL The remote control box that is included with your PSC Power Star LiFE serves several func...

Page 9: ...tive SpeakOn Connector used to external battery connection CHARGING Power Star LiFE contains a built in charger designed to charge the internal LiFE battery and also charge any external LiFE battery s...

Page 10: ...ed that you have your cables built by qualified personnel and tested prior to use with your Power Star LiFE All power cables should be clearly labeled on both ends as to what they are to be connected...

Page 11: ...fuse should never blow in normal use If you ever experience a blown fuse something is wrong with your setup Please call PSC for technical assistance STORAGE Please note that all rechargeable batterie...

Page 12: ...only Furthermore Professional Sound Corporation warrants the remaining electronics housing and other parts to be free from defective material and workmanship for a period of one year from the origina...

Page 13: ...TPUT VOLTAGE 12 8Vdc Nominal OUTPUT CURRENT On LiFE Battery 25 Amps AC only 24 Amps CHARGING TIME Typical Cart 1 5 hours No Load all equipment off 1 hour USB CHARGING PORT 4 Ports Total Output 5Vdc at...

Page 14: ...tem RESPONSIBLE PARTY Professional Sound Corp 28085 Smyth Drive Valencia CA 91355 USA CONTACT PERSON Ronald Meyer 661 295 9395 TYPE OF PRODUCT Rechargeable Battery Power Distribution MANUFACTURER Prof...