PSC Power Star Element Operation Manual Download Page 2

Thank  you  for  purchasing  your  new  PSC  PowerStar  Element  re-chargeable  power  distribution 
system.   This new power system combines an External Battery Charger with a compact unit that 
includes: Power Distribution, Power Filtering, Monitoring and Protection Circuitry.  We believe 
this design provides a great solution for use both at home and while traveling. 

 

PLEASE  BE  SURE  THAT  YOU  HAVE  READ  AND  UNDERSTOOD  THIS  ENTIRE  OPERATIONAL  MANUAL 

BEFORE OPERATING THE PSC POWERSTAR ELEMENT! 

CAUTION! DO NOT LIFT THE BATTERY WEIGHT BY LIFTING ON THE POWESTAR ELEMENT.  DO NOT DROP 

THE  BATTERY/POWERSTAR  ELEMENT  COMBINATION.    PLEASE  HANDLE  THIS  BATTERY/POWERSTAR 

ELEMENT COMBINATION WITH CARE AT ALL TIMES.   DO NOT SHORT CIRCUIT ANY BATTERY TERMINALS 

AS ELECTRICAL SHOCK AND OR EQUIPMENT DAMAGE MAY RESULT.  ALWAYS TREAT RECHARGEABLE 

BATTERIES  WITH  GREAT  CAUTION.  ALL  AUXILARY  EQUIPMENT  SHOULD  BE  REVERSE  POLARITY 

PROTECTED AND PROPERLY FUSED AT ALL TIMES. 

THE  POWER  STAR  ELEMENT  IS  DESIGNED  FOR  USE  WITH  EITHER  A  SEALED  LEAD  ACID  CHEMISTRY 

BATTERY OR WITH A LiFEPO4 (LITHIUM IRON PHOSHATE) BATTERIES ONLY.   THE SUPPLIED CHARGER IS 

DESIGNED TO CHARGE THESE TWO TYPES OF BATTERIES ONLY!  THE INCLUDED BATTERY CHARGER IS 

FACTORY ADJUSTED FOR PROPER CHARGING OF THESE BATTERY TYPES ONLY!  

 

Professional Sound Corporation 

28085 Smyth Drive 

Valencia, CA  91355 USA 

Ph (661) 295-9395 

[email protected]

     

www.professionalsound.com

 

 

Summary of Contents for Power Star Element

Page 1: ...PSC POWER STAR ELEMENT TM Operation Manual Version 1 0 Copyright 2020 Professional Sound Corp 28085 Smyth Drive Valencia CA 91355 USA CE RoHS Printed in the U S A...

Page 2: ...NATION PLEASE HANDLE THIS BATTERY POWERSTAR ELEMENT COMBINATION WITH CARE AT ALL TIMES DO NOT SHORT CIRCUIT ANY BATTERY TERMINALS AS ELECTRICAL SHOCK AND OR EQUIPMENT DAMAGE MAY RESULT ALWAYS TREAT RE...

Page 3: ...attery to use with the device when you arrive at your location shoot This eliminates having to deal with shipping any lithium batteries Never ship your PSC PowerStar Element while it is attached to an...

Page 4: ...ON THUMB SCREWS This device was designed to be used with commonly found 12 volt 33 to 35 Amp Hour Sealed Lead Acid SLA batteries This size and style of battery was chosen as it is the most common size...

Page 5: ...ICA TYPICALLY HAVE FLAT TERMINALS THAT STICK UP OUT FROM THE BATTERY BATTERIES SOLD IN MANY PARTS OF EUROPE AND ASIA HAVE 6MM SCREW TERMINALS EVERY POWERSTAR ELEMENT COMES WITH A PAIR OF BRASS TERMINA...

Page 6: ...adaptors to the battery before proceeding Please note that the part that screws down onto the 6mm battery terminal is slotted to allow overall terminal width adjustment Please install the brass termin...

Page 7: ...d call PSC for help 7 GENTLY insert the two thumb screws into the holes on the front side of the PowerStar Element and start threading them in a CLOCKWISE direction Righty Tighty 8 Make sure the threa...

Page 8: ...rger fully enclosed such as in a drawer or packed tightly within other equipment It must have some free space around every side of the body of the charger in order that it dissipate heat correctly Fai...

Page 9: ...ttery Fuel Gauge POWER SWITCH The main power switch is centrally mounted It is a Momentary type of toggle switch You press and hold it momentarily upward to turn the unit ON You momentarily hold it do...

Page 10: ...eft most RED LED goes out the unit will automatically shut down to protect the battery from deep discharge The unit must then be connected to the supplied PSC battery charge to re charge the battery a...

Page 11: ...ic and thus does not require your assistance in any way Simply plug the supplied battery charger into the PSC PowerStar Element and the charging begins when needed Be aware that the PowerStar Element...

Page 12: ...age drop across the cable WARNING It is highly recommended that you have your cables built by qualified personnel and tested prior to use with your PowerStar Element All power cables should be clearly...

Page 13: ...nection is protected against faults and short circuits using a 40A automotive blade type fuse It has been placed there as a Fail Safe in case anything was to ever go drastically wrong This fuse should...

Page 14: ...ssional Sound Corporation Shipping and insurance costs to and from Professional Sound Corporation must be prepaid by the owner This warranty does not cover damage due to accident careless handling abu...

Page 15: ...UTPUT CURRENT On Battery 15 Amps Maximum 10 Amps Continuous CHARGING TIME No Load all equipment off 1 3 hours LiFEPO4 BATTERY CAPACITY 12 8 Volts 50 Amp Hours or less CHARGER CONNECTOR SpeakOn 2 Pole...

Page 16: ...tion System RESPONSIBLE PARTY Professional Sound Corp 28085 Smyth Drive Valencia CA 91355 USA CONTACT PERSON Ronald Meyer 661 295 9395 TYPE OF PRODUCT Power Distribution Charger MANUFACTURER Professio...

Reviews: