3

Technical data

PARAMETER

VIB 6.122 R / DEX
VIB 6.125 R / RIP / IDEX
VIB 6.142 R / DEX

VIB 6.127 / DEX
VIB 6.129 IP / IDEX
VIB 6.147 / DEX

Measur

ement

Signaling system

Current Line Drive (CLD)

Transmission factor
(Ref.: 159 Hz; 25 °C [77°F]) 

1.0 µA/ms

-2  

[9.8 µA/g] ± 3%

5.35 µA/ms

-2  

[52.43 µA/g] ± 4%

Frequency range 

± 3dB

1 Hz  ...  20 kHz

0.3 Hz  ...  12 kHz

Resonance frequency

36 kHz

17 kHz; > 20 dB damped

Linearity range 

± 10%

± 961 ms

-2 

 [± 98g]

± 450 ms

-2  

[± 46g]

Transverse sensitivity

< 5 %

Electrical

Power supply

> 10 mA / 7-18 VDC

Noise, rms

<  0.01 ms

-2

 as of 2 Hz

<  0.002 ms

-2

 as of 2 Hz

Output impedance

> 1 MOhm (VIB 6.12**)
> 0.3 MOhm (VIB 6.14 R / DEX)

> 0.3 MOhm

Electrical insulation

> 10

9

 MOhm

Envir

onment

Degree of protection

IP 65 w/ cable connected
IP 67 w/ straight protective cap and clamp rings
IP 68 w/ cable option VIB 6.760 / VIB 6.761 (only for series VIB 6.1**IP)

Shock resistance

< 250 kms

-2 

[25000 g]

< 50 kms

-2 

[5000 g]

Temperature sensitivity

<  0.05 ms

-2

/K 

<  0.01 ms

-2

/K

Magnetic sensitivity

<  5 ms

-2

/T (at 50 Hz)

<  1 ms

-2

/T (at 50 Hz)

Base strain sensitivity

<  0.1 ms

-2

/µm/m

Temperature range,
w/ cable VIB 90093
(

1

 w/ cable VIB 90007)

- 30 °C ... + 80 °C [-22 °F ... + 176 °F] (VIB 6.1**DEX)
- 40 °C / °F ...
... + 100 °C [+ 212 °F] (VIB 6.122 R, VIB 6.142, VIB 6.127, VIB 6.147)
... + 125 °C [+ 257 °F] (VIB 6.125 R, VIB 6.125 RIP, VIB 6.129 IP)
... + 135 °C [+ 275 °F] (VIB 6.125 R, VIB 6.125 RIP, VIB 6.129 IP)

1

Mechanical

Case material

Stainless steel VA 1.4305
Stainless steel

 VA 1.4571 (VIB 6.125 RIP / IDEX,  VIB 6.129 IP / IDEX)

Weight

38 ... 43 g [1.3 ... 1.5 oz]

Socket

TNC

Mounting thread

M8, 90° cone (VIB 6.12x)
M5, flat (VIB 6.14x) 

Mounting height A

> 120 mm / 60 mm (straight / angled plug)
> 140 mm / 120 mm (w/ IP68 cable option VIB 6.760 / VIB 6.761)

Summary of Contents for FLUKE VIB 6.12 Series

Page 1: ...Accelerometer Industrial VIB 6 12x VIB 6 14x Installation and Operation ...

Page 2: ...he Ex zone Only sensors of series VIB 6 1 DEX are permit ted to be operated in the Ex zone Sensors of series VIB 6 1 DEX are only to be connected to certified intrinsically safe circuits giving due consideration to the following max imum values Ui 24 V Pi 300 mW Ci 15 nF Li negli gibly small The permissible ambient temperature range is between 30 C and 80 C 22 F 176 F The European installation reg...

Page 3: ...P 67 w straight protective cap and clamp rings IP 68 w cable option VIB 6 760 VIB 6 761 only for series VIB 6 1 IP Shock resistance 250 kms 2 25000 g 50 kms 2 5000 g Temperature sensitivity 0 05ms 2 K 0 01ms 2 K Magnetic sensitivity 5ms 2 T at 50 Hz 1ms 2 T at 50 Hz Base strain sensitivity 0 1ms 2 µm m Temperature range w cable VIB 90093 1 w cable VIB 90007 30 C 80 C 22 F 176 F VIB 6 1 DEX 40 C F ...

Page 4: ...ing out the hole Solvent for degreasing Threadlocker LOCTITE 243 Select the point of installation The drilled hole must have direct connection to the bearing carrier if the sensor should measure shock pulse signals Minimum distance between the drilled hole and protruding edges of the housing must be 35 mm A Allow adequate clearance to attach the wrench Note Ensure that a hole can be drilled at the...

Page 5: ...he adhesive for use Apply the adhesive with a wooden spatula evenly to the base of the mounting adapter and the bonding location approx 1 mm thick I Affix mounting adapter Press the adapter gently against the bonding lo cation and turn it to evenly distribute the adhe sive If applicable screw in the centering pin J Do not remove excess adhesive If necessary apply additional adhesive around the bon...

Page 6: ...a cable duct or protective tube Use cable ties and Velcro fasteners to fix the ca bles in place Do not lay cables parallel to power lines Adhere to the minimum spacing 1 m Lay a loop with sufficient reserve traction ahead of a cable gland Label the cable ends to avoid getting them mixed up Extend the cable Observe the maximum cable lengths see the device installation manual Use appropriate coaxial...

Page 7: ...ntial equalization A line resistance of 120 mOhm is recommend ed for interference protection reasons 1 5 mm 10 m Due consideration is to be given to personnel goods lightning explosion protection as well as other protection types where appropriate for the respective customer trade association insurer state federal government etc In this regard the relevant implementation pro visions are to be obse...

Page 8: ... C Protective terminal housing plastic D Protective terminal housing metallic mounted and insulated housing at PA E Outer shield not laid F Protective cap w clamp ring or IP68 cable option VIB 6 760 6 761 PA potential equalization Connection examples for the Ex zone VIBSCANNER EX PA PA CMS without EX protection Um 250V PE Not connected PA VIB 3 550 50 mm EX i Coaxial VIBXPERT EX Machine A C D Tria...

Reviews: