Prozeda SOLAREG II VISION plus Operating Manual Download Page 24

12 Warranty 

conditions

The SOLAREG II controllers are carefully produced and tested on an automatic 
testing station. If any failures occur, fi rst check if there are any operation / setting 
or system errors. Furthermore, check the pump and temperature sensor connec-
tions.

PROZEDA GmbH provides a 2-year warranty starting at the date of purchase and 
according to the following conditions.

a)    The warranty comes into eff ect if the purchased good exhibits a material or 

quality defect. If the defect is caused by improper handling, by exceeding the 
permitted values stated in the specifi cations, improper wiring, invalid tech-
nical modifi cations to the device performed by the buyer or by an another 
company other than PROZEDA GmbH, the warranty shall be void.

b)    The warranty requires a written notice that describes the defect in detail as 

well as a copy of the customer invoice.
PROZEDA GmbH can choose to fulfi l the guarantee, at its own discretion, by 
one of the following measures
- Repair (reconditioning) or
- Delivery of a fully functional replacement product
The device shall be repaired within 1 month after PROZEDA GmbH has re-
ceived it. 
If the device is not repaired within the two repairs attempts, the buyer is 
entitled to delivery of a fully functional replacement product.
If a replacement product is delivered, a new warranty that corresponds to 
these conditions shall come into eff ect.

c)    Any further warranty (redhibitory action, reduction of price) is excluded.

Warranty claims may only be submitted by the customer and are non-transfer-
able.

If a defect occurs during the warranty period, please contact the supplier / in-
staller. When returning the device for warranty service, please make sure to send 
a description of the error and, if possible, the system diagram along with the 
wiring diagram.

 

13  Declaration of conformity

We, Prozeda GmbH, declare under our sole responsibility that the SOLAREG type 
1316 product complies with the following standards:

EMC Directive 89/336/EEC, amended by RL 92/31/EEC and RL 93/68/EEC

EN 50081-1:1992 / EN55022:1998 (Radiated Emission)

  

EN 50082-1: 1997 / EN 61000-4-2:1995/A1:1998 (ESD)

  / EN 61000-4-3:1996+A1:1998 (Radiated Immunity)

  / EN 61000-4-4:1995 (Burst)

  / EN 61000-4-5:1995 (Surge)

  / EN 61000-4-6:1996 (Conducted Immunity)

  / EN 61000-4-11:1994 (Voltage Drops)    

Operation manual for SOLAREG II VISION PLUS 

1316BED026-20B-E, last revised 01/2008

24

Summary of Contents for SOLAREG II VISION plus

Page 1: ...Microcontroller controlled temperature difference controller for solar thermal systems Operatingmanual Operatingmanual Solareg II VISION plus...

Page 2: ...conditions 24 13 Declaration of conformity 24 The number of displayed values depends on the activated additional functions The number of displayed values depends on the activated additional functions...

Page 3: ...Real time clock function Available accessories Temperature sensor PT1000 Yield measurement set incl tube sensor Sensor connection box Immersion sleeves 2 Safety instructions Always completely disconne...

Page 4: ...Quick Info card provided with the device into the pocket provided on the back of the device The Quick Info card provides the user with an overview of the functions to facilitate rapid device operatio...

Page 5: ...cope 2 to 6 sensors are required Mounting wiring the temperature sensors Mount the sensors on the collector and the storage tank Ensure proper heat transfer and use heat conducting paste if necessary...

Page 6: ...Confirm a value change and store it 5 Menu structure 5 1 Info menu The following measured and yield values are displayed in the Info menu Display e g Meaning Can be reset 75 C Displays current collec...

Page 7: ...permis sible temperature 15 95 C 65 C dT max 7K Storage tank 1 2 Switch on differ ence 3 40K 7K dT min 3K Storage tank 1 2 Switch off differ ence 2 35K 3K min 100 12 Set the minimum pump capacity usi...

Page 8: ...n the Basic Setup menu Settings must only be changed by a specialised technician Settings may only be adjusted in the menu a within one minute after the device has been switched on or b after simultan...

Page 9: ...tank systems Controller response time in s 30 480 240 10 1 First priority storage tank selection 1 2 1 11 0 Anti freeze function 0 Off 1 On 0 12 6 Anti freeze function Reference sensor selec tion 1 6...

Page 10: ...onductor mains and outputs A1 Solar circuit pump switching output 1 A2 No function A3 Independent controller switching output 3 Sensor connections S1 Collector sensor S2 Lower storage tank S3 No funct...

Page 11: ...eter Type 1 one collector two storage tanks with a three way valve A2 Off The valve must es tablish the connection between the collector and storage tank 1 Type 1 one collector two storage tanks with...

Page 12: ...itching output 1 A2 Pump switching output 2 A3 Independent controller switching output 3 Sensor connections S1 Collector sensor S2 Lower storage tank 1 S3 Lower storage tank 2 S4 Collector return S5 O...

Page 13: ...ler other temperature display S7 Option flow meter Type 3 two collectors one storage tank with a three way valve The valve must es tablish the connection between collector 1 and the storage tank Type...

Page 14: ...outputs A1 Solar circuit pump 1 switching output 1 A2 Solar circuit pump 2 switching output 2 A3 Independent controller switching output 3 Sensor connections S1 Collector array 1 S2 Lower storage tan...

Page 15: ...n the charging duration as well as an interruption of this func tion along with a waiting period to monitor the collector temperature Basic Setup menu Display Meaning Value range Factory set ting Line...

Page 16: ...9 23 59 Heating If the measured temperature is below the target value output A3 is switched on until the measured temperature reaches the target value hysteresis Basic Setup menu Display Meaning Value...

Page 17: ...erature differ ence controller function can also be selected 0 Off 1 Cooling 2 Heat ing 3 Tem perature difference controller 0 15 5 Sensor selection for the independ ent controller source 1 6 5 Progra...

Page 18: ...only effective if the storage tank temperature is below the temperature limit 95 Therefore during the holiday period for example the storage tank is discharged at night to the set recooling temperatur...

Page 19: ...y yield measurement The energy yield of the solar power system is calculated and displayed using the temperature difference between the collector and the collector return tempera ture and the measured...

Page 20: ...d short circuits Errors are indicated by the symbol You can find the error source by scrolling up or down the Info menu 8 2 Flow monitoring The controller is programmed to display a message if the flo...

Page 21: ...ensor if necessary Flashing Short circuit in the sensor cable Check cable Defective sensor Check sensor resistance and replace sensor if necessary Circulation error No flowSFlb Flashing Additional dis...

Page 22: ...r Outputs are not switched on Controller is in manual operation Exit Manual operation Switch on condition is not satisfied Wait until switch on condition is satisfied Pump symbol rotates but the pump...

Page 23: ...ing output Total power of all outputs 230V 1A approx 230VA for cos 0 7 1 0 2A approx 460VA maximum Fuse protection Fine wire fuse 5 x 20mm 2A T 2 amperes delayed action fuse Miscellaneous Recommended...

Page 24: ...d within 1 month after PROZEDA GmbH has re ceived it If the device is not repaired within the two repairs attempts the buyer is entitled to delivery of a fully functional replacement product If a repl...

Reviews: