8
5.4 "Basic Setup" menu
The main functions are displayed in the Basic Setup menu. Settings must only be
changed by a specialised technician.
Settings may be adjusted only when you enter the menu within one minute after
the device has been switched on.
Display
Meaning
Value range Factory
setting
Current
setting
Line Value
0
0
Collector protection
function
0 = Off
1 = On
0 = Off
1
120 °C
Collector protection
function
110 –150°C
120°C
2
0
Recooling function
(only if the collector
protection is on)
0 = Off
1 = On
0 = Off
3
40°C
Recooling temperature
30 –90°C
40°C
4
0
Tube collector function,
time-controlled
0 = Off
1 = On
0 = Off
5
0
Function
Energy yield measure-
ment
0 = Off
1 = On
0 = Off
6
0
Selection of cooling or
thermostat function
0 = Off
1 = Cooling
2 = Heating
0
Settings and changes in
this menu must only be
carried out by a specialised
technician. Incorrect settings can
damage or adversely affect the