Displaying and changing the values in the menus
22
Menu item
Description
Condition time
This parameter is used to set how long the conditions for switching
on and off must be active in order to take effect.
Recooling
Function
Switch the "Recooling" function on or off
Recooling temp
The temperature to which the storage tank is recooled after the
"Collector protection" function was active
Tube collector
Function
Switch on the "Tube collector" function in the required control type
(time-controlled/control via temperature change/radiation-
controlled).
Switch off the "Tube collector" function.
Pump runtime
Pump runtime of the "Tube collector" function
Interval
Interval time between the pump runtimes
Time
Interval period for control via temperature change
deltaT
Temperature for control via temperature change
Anti-freeze
Function
Switch the "Anti-freeze" function on or off
Sensor
Select the sensor input
Temperature
Temperature at which the "Anti-freeze" function becomes active
System protection
Temperature
Temperature at which the "System protection" function becomes
active
Pump type R1/R2/R3
You can choose between the following pump types at the R1/R2/R3
switching output:
– 230 V block modulation
– Analog (R1 and R2 only)
– PWM
– PWM inverted.