2. Grounded, cord-connected tools intended for use on a
supply circuit having a nominal rating less than 150 volts:
This tool is intended for use on a circuit that has an outlet
that looks like the one illustrated in Sketch A in Figure 7.
The tool has a grounding plug that looks like the plug
illustrated in Sketch A in Figure 7. A temporary adapter,
which looks like the adapter illustrated in Sketches B and
C, may be used to connect this plug to a 2-pole receptacle
as shown in Sketch B if a properly grounded outlet is not
available. The temporary adapter should be used only until
a properly grounded outlet can be installed by a qualified
electrician. The green-colored rigid ear, lug, and the like,
extending from the adapter must be connected to a
permanent ground such as a properly grounded outlet box.
Grounding methods
Table 1
Minimum gage for cord
Effective date for Table 1 changed from November 1, 1995
to November 11, 1996
Ampere Rating
Volts
Total length of cord in feet
120 V 25 ft. 50 ft.
100 ft.
150 ft.
240 V 50 ft. 100 ft.
200 ft.
300 ft.
More
Not More
AWG
Than
Than
0
6
18
16
16
14
6
10
18
16
14
12
10
12
16
16
14
12
12
16
14
12
Not Recommended
Legend (fig, 1)
1. Speed controller
2. On/off switch
3. Working table
4. Angular limit stop clamping bolt
5. Angular limit stop
6. Angular limit stop scale
7. Housing
8. Mains cable
9. Spigots for duct extract unit
10. Clamping bolt for working table adjustment
11. Working table adjustment scale
12. Indicator needle
13. Protective cover
14. Disk sander disk with abrasive disk
15. Spigots for cooling unit
16. Spigots for coolant pipes
Description of the Unit
This disk sander can be used to precisely grind all types of
wood, non-ferrous metals, steel, plastic, cork, rubber and
glass. The stepless speed control permits the grinding
characteristics to be optimally matched to any material.
The working table is manufactured from die-cast aluminium
with a ground surface finish. Self-adhesive abrasive disks
can be readily replaced. The disk sander has dual ball-
bearing mounts and the front face of the unit is plane-
turned.
Warning !
This Disk sander is for indoor use only. Do not expose to
rain or use in damp locations.
Warning !
For your safety, never connect the plug to the power
source receptacle until the assembly and adjustment steps
are completed, and you have read and understood the
safety and operating instructions.
GROUNDING
ADAPTER
GROUNDING
GROUNDING
MEANS
METAL SCREW
COVER OF GROUNDED
OUTLET BOX
<A>
<B>
<C>
<D>
PIN
PIN
Fig. 7