49
A) Use remote management to access the RangeLAN2 7500.
If this fails, check the Ethernet cabling.
B) Use the RL2SETUP program on a wireless client and
perform a site survey. If you cannot see the RangeLAN2
7500, you may be using the wrong domain.
C) Check the filter settings on the RangeLAN2 7500. Verify
that you are not filtering out the kind of traffic you are
trying to send. For example, on a Novell network, you do
not want to check the IPX protocol box. On an IP net-
work, you may need to set an ARP filter.
D) Verify the Access Point diskette is seated properly inside the
RangeLAN2 7500.
RangeLAN2 7500 LEDs
There are three LEDs on the front panel of the RangeLAN2
7500:
❑
The Power LED should be on whenever the RangeLAN2
7500 is powered on.
❑
The LAN1 LED flashes to indicate RangeLAN2 transmis-
sions on the network.
❑
The LAN2 LED flashes to indicate Ethernet transmissions on
the network.