9. The Edit Mode

The edit mode provides access to the PEC-2’s detailed parameters. All edit parameters are accessed by pressing the MODE
switch for longer than 3 seconds to enter the EDIT mode, and then using the DEC/- and/or INC/+ switches to select the desired
parameter.

The Edit Mode Menu

The nine parameters accessible via the edit mode are described below. The parameters are identified by abbreviations on the
display. Please refer to the descriptions below for the meanings of the display abbreviations. In some cases you may also need
to refer to section 7, “Technical Details”.

1)Memory Protect

This function prevents unwanted changes to the contents of the 84 program memories. We recommend that you turn the mem-
ory protect function on before a performance to prevent accidents. The initial default setting is “off.”
In the edit mode use the DEC/- and/or INC/+ switches to select edit menu number 1 (“1Pr”) and press the ENTER switch. You
can  then  use  the  INC/+  and  DEC/-  switches  to  turn  the  memory  protect  function  on  or  off,  respectively.  Once  the  required
selection has been made press the ENTER switch to confirm the selection and return to the edit menu.

2)Link Mode

The Link mode has three possible settings: LINK, MASTER, and SLAVE. The initial default setting is LINK. When using the PEC-
2 alone be sure to set this parameter to LINK or MASTER.
In the edit mode use the DEC/- and/or INC/+ switches to select edit menu number 2 (“2Lr”) and press the ENTER switch. You
can then use the INC/+ and DEC/- switches to select LINK, MASTER, or SLAVE. Once the required selection has been made
press the ENTER switch to confirm the selection and return to the edit menu.

3)Mute Disengage Mode

The Mute Disengage Mode can be set to either AUTO or MANUAL. The initial default setting is AUTO.
In the edit mode use the DEC/- and/or INC/+ switches to select edit menu number 3 (“3Mt”) and press the ENTER switch. You
can then use the INC/+ and DEC/- switches to select AUTO or MANUAL. Once the required selection has been made press the
ENTER switch to confirm the selection and return to the edit menu.

Summary of Contents for PEC-2

Page 1: ...Rev 1 4 PPD0830 03...

Page 2: ...this owner s manual thoroughly and keep it in a safe place for future reference CONTENTS 1 PEC 2 Main Features 3 2 Precautions 3 3 Quick Start Guide 4 4 Front Panel Nomenclature Operation 5 5 Rear Pan...

Page 3: ...nnectors provided for easy integration with MIDI control systems Link Mode allows two PEC 2 units to be linked for control of up to 16 loops the loops of each PEC 2 unit can be switched individually R...

Page 4: ...rams 12 x 7 In the PEC 2 PGM mode banks are selected via the BANK and BANK switches and individual programs are selected via the PGM1 PGM7 switches The currently selected bank and program are shown on...

Page 5: ...nts the selected parameter in the EDIT mode MUTE Switch When this switch is engaged and the MUTE LED is flashing a mute circuit located between LOOP 5 and the OUT 1 and OUT 2 jacks is activated so tha...

Page 6: ...feed the signal from either the buffered or non buffered input to the tuner IN LOOP6 LOOP8 Inputs for the PEC 2 s three separate loops S 6 S 8 Sends 6 8 Normally Closed These are the send jacks for s...

Page 7: ...PEC 1 were re examined and re designed to reduce switching noise to an absolute minimum Separate Loops 1 Loops 6 through 8 are totally independent and use the same precision mechanical relays as loop...

Page 8: ...IRECT mode the loops on either unit can be directly turned on or off as required 2 REMOTE Mode With this function you could place one PEC 2 unit on stage and another in the wings and use one or the ot...

Page 9: ...minated When the loop is off Output 2 is selected and Output 1 is muted Connect the input signal to the IN jack the send jack S 6 S 7 or S 8 to one amplifier or other device and the OUT jack to the se...

Page 10: ...ch You can then use the INC and DEC switches to turn the memory protect function on or off respectively Once the required selection has been made press the ENTER switch to confirm the selection and re...

Page 11: ...when the corresponding switch is pressed In the edit mode use the DEC and or INC switches to select edit menu number 6 6cc and press the ENTER switch You can then use the INC and DEC switches to selec...

Page 12: ...after completing step 3 above press the INC 1 switch one more time so that tdt transmit data appears on the display then press ENTER YES will flash on the dis play Press ENTER again and data transmis...

Page 13: ...13 10 System Examples...

Page 14: ...14...

Page 15: ...rbox Provolt9 PV 9 DC9V Output Connectors x 6 Double Filtering on each of the Provolt9 outputs ensures exceptionally clean power supply The Provolt9 Auto Voltage Controller ensures that approximately...

Page 16: ...3 21 7 Tsurumi Chuo Tsurumi ku Yokohama shi Kanagawa 203 0051 JAPAN TEL 81 45 510 4060 FAX 81 45 510 4061 E MAIL overseas1 pacifix ltd com www providence ltd com...

Reviews: