STUDY THIS MANUAL CAREFULLY

The boiler (as well as all its optional 
accessories) complies with the 
requirements of European Directive 
90/396/EEC on gas-fuelled appliances 
and European Directive 92/42/EEC 
on ef

fi

 ciency, the European Directive 

2006/95/EC on electrical means of 
operation for use in certain voltage ranges 
and the European Directive 89/336/EEC 
on electromagnetic compatibility. 

The appliance is also approved according 
to the European norms EN 677, EN 625, 
EN 60335-01, EN 50165, EN 55014, EN 
61000-3-2 and EN 61000-3-3.

In order to operate and handle the boiler 
in accordance with the purpose for which 
it is designed in actual conditions of use 
(hereafter referred to only as use), it is 
necessary to abide also by additional 
conditions – the most essential of which 
(i.e. those which must not be omitted) 
are found in the following regulatory 
documents: 

- in the design area: STN 06 0310 and 
STN 06 0830;

- in the 

fi

 re safety area: STN 92 0300;

- for installation and 

fi

 tting (and repairs): 

STN EN 1755 or STN 38 6460, as 
applicable STN 38 6462, Decree no. 
48/1982 Coll. (as amended by the 
later prescriptions) and the binding 
occupational health regulations;

- in time of running and operation: STN 38 
6405;

- in the area of discharge of combustion 
gases and air in

fl

 ow STN EN 483, 

company material – “catalogue of dual 
piping for discharge of combustion gases 
and in

fl

 ow of combustion air designated 

for type C gas appliances, i.e. in closed 
“TURBO” version.

The boiler is designated for operation 
within the normal AA5/AB5 environment in 
compliance with STN 33 2000-3 and STN 
33 2000-5-51 (i.e. a temperature range of 
5 – 40°C, temperature-dependent humidity 
to a max. of 85%).

GEPARD boilers are suitable for the 
conditions of zones 1, 2 and 3, in rooms 
with a bath or shower and in washing 
areas as set out in STN 33 2000-7-701; 
they may not be installed in zone 0 (Fig.8). 
Before installation in the areas mentioned, 
protection against electric shocks must be 
provided for according to the same norms.

The boiler complies with Ministry of Health 
Decree No 13/1977 Coll., i.e. on noise, for 
installation in residential and public areas.

The boilers are built to operate with 
heating water, in compliance with STN 07 
7401. (Above all, the water must never 
be acidic, i.e. its pH must be higher than 
7 and it should have minimal carbonate 
hardness.)

The requirements regarding the 
characteristics of domestic water are 
set out in STN 83 0616 (potable water 
STN 75 7111). With regards to water with 
total material concentrations of calcium 
and magnesium greater than 1.8 mmol/l, 
further “non-chemical“ measures against 
scale deposits (e.g. operation of magnetic 
water treatments in combination with 
settling equipment) are advisable.

Silting up of the boiler with contaminants 
from the heating system or the settling of 
boiler scale on these disturbances, or on 
induced disturbances (e.g. silting up of the 
exchanger, pump breakdowns) are not 
covered by the boiler warranty.

The distance from 

fl

 ammable materials 

(e.g. PVC, 

fi

 breboard, polyurethane, 

synthetic 

fi

 bres, rubber etc.) must be 

Summary of Contents for Gepard 23 MOV v.19

Page 1: ...23 MOV v 19 23 MTV v 19 Wall hang non condensing boiler Power 8 5 23 3 kW Flow heating HW Gepard ve r s i o n User manual EN...

Page 2: ......

Page 3: ...ls 5 1 7 Using the device Obligations of the manufacturer 5 2 7 Recycling 6 7 Packing list 7 8 HOW TO USE THE BOILER Using the equipment 8 9 Overview 8 1 9 Turning on and off 8 2 9 User settings 8 3 9...

Page 4: ...oubleshooting 9 24 Safety regulations 10 26 Servicing and maintenance of the boiler 11 26 Cleaning 11 1 26 Regular servicing 11 2 26 Replacement parts 11 3 26 Regulations 12 26 Converting to different...

Page 5: ...s quick start manual 1 2 We have prepared this User s manual to help you start to use your equipment right away It is assumed in this manual that the equipment has been installed and commissioned by...

Page 6: ...type C gas appliances i e in closed TURBO version The boiler is designated for operation within the normal AA5 AB5 environment in compliance with STN 33 2000 3 and STN 33 2000 5 51 i e a temperature...

Page 7: ...alid norms If any maintenance repair or adjustments concerning the gas are needed a qualified technician must be called PROTHERM has developed tailor made accessories that will help you use your heate...

Page 8: ...e boiler Do not under any circumstances destroy or remove the sealing from any of the parts Never carry out alone any maintenance or repairs to the equipment Only qualified technicians may work with t...

Page 9: ...aintenance instructions of the manufacturer All servicing maintenance repairs dismantling of or working with the equipment during the warranty period is carried out by a qualified technician only Repa...

Page 10: ...10 Protherm 8 STUDY THIS MANUAL CAREFULLY Packing list 7 1 2 3 6 7 4 5 8 9 Legend 1 Boiler 2 Draw bar 3 Exhaust gas diffuser only for MTV 4 Sealing 5 Template 6 Butt end of water intake 7 Butt end of...

Page 11: ...situation the system pressure must be topped up by letting in water Once the pressure in the system reaches a value of 0 5 bar display shows real time status of the boiler again if pressure rises abo...

Page 12: ...faulty setting of the boiler or room regulator On OFF regulator 8 4 3 The boiler will maintain the selected CH temperature Boiler operation is interrupted turned on and off according to the internal...

Page 13: ...aration distances of the interconnected individual intakes and outlets The heating system circuit should be connected to the boiler in such a way that during repairs to the boiler the heating water ne...

Page 14: ...al parameters on end of this manual Discharging water from the boiler 8 9 The outlet valve is designated primarily for lowering the water pressure in the boiler during repairs Only a partial discharge...

Page 15: ...ring the operation of the boiler The safety valve furthermore may not be used for releasing water from the boiler or the heating system The settling in the valve of detritus from the heating system is...

Page 16: ...ger 4 Discharge valve 5 Burner 6 Ignition electrodes 7 NTC CH water intake temperature sensor 8 Combustion chamber 9 CH exchanger 10 Exhaust gas collector 11 Combustion thermostat 12 NTC CH return wat...

Page 17: ...r 4 Discharge valve 5 Burner 6 Ignition electrodes 7 NTC CH water intake temperature sensor 8 Combustion chamber 9 CH exchanger 10 Exhaust gas collector 11 Ventilator 12 Air manostat 13 NTC CH return...

Page 18: ...iping slope at a gradient sufficient to let the condensation drain towards an outside area or towards a receptacle designed to draw off condensation To achieve this the elbow joint may be gently bent...

Page 19: ...rom independent boilers independent routes can feed into shared chimneys the transport capacity of the chimney is judged according to the manufacturer s data on the chimney If the pipes are set into t...

Page 20: ...ing Length of fume ducting 23 MTV 80 80 min 2 x 0 5 m max 2 x 18 m If the total fume ducting length is more than 2 x 2 m the diffuser with a diameter of 39 mm must be removed The C 8 15 6 82 method Us...

Page 21: ...t least 1 2 m3 of air hour per kW of boiler output must be available Piping gradient 8 15 8 The layout of the piping must permit a down gradient of the exhaust piping towards the boiler at a nominal g...

Page 22: ...ll are a 0 5 m b 1 0 m c 5 0 m a1 depending on x as follows x 5 0 m then a1 0 5 m x 4 0 m then a1 0 6 m x 3 0 m then a1 0 75 m x 2 0 m then a1 1 0 m x 1 0 m then a1 1 2 m Dual apertures set vertically...

Page 23: ...3 2000 4 46 It must always have the protective ground pin reliably connected with the PE or PEN wire a combination of green and yellow colours The boiler must always be connected through its main to t...

Page 24: ...g of the boiler The room regulator leads are connected to the terminal board of the boiler By means of the above mentioned regulators the isothermal regulation function can be activated All settings f...

Page 25: ...9 20 18 17 16 15 14 13 12 11 4 2 3 1 3 4 2 1 X2 1 2 1 1 1 1 1 10 2 11 3 12 4 13 5 14 6 15 7 16 8 17 9 18 X20 1 2 3 4 1 1 2 1 X21 18 17 16 15 2 1 3 4 5 9 7 6 8 10 11 12 14 X11 13 Legend 1 Regulation co...

Page 26: ...n temperature sensor F2 Failure of NTC HW sensor F3 Failure of NTC accumulator F4 Disruption of NTC collector F5 Failure of air supply sensor F6 Failure of draw sensor F7 Disruption of NTC HW return f...

Page 27: ...F36 Draft detected chimney version only F37 Ventilator rpms during operation are outside tolerance limits F38 Measured frequency limit is outside tolerance limits F39 Error in boiler auto detection F...

Page 28: ...these may harm the paintwork Regular servicing 11 2 Regular servicing is very important in ex tending the lifecycle and safe and efficient use of your device b Incorrect or inappropriate servicing ma...

Page 29: ...rent fuel must be carried out by an authorised technician with a valid manufacturer s certificate For conversion to propane use the conversion kit for switching from natural gas to propane gas The kit...

Page 30: ...onsumption m3 h 1 10 Maximum gas consumption kg h 2 64 Minimum gas consumption kg h 1 13 NOx classification 3 Gas pressure Inlet pressure mbar 20 37 Membrane diameter mm 5 8 4 4 Maximum pressure in di...

Page 31: ...mperature range C 38 60 Electrical data Voltage frequency V Hz 230 50 Consumption W 92 Electrical casings IPX4D Current A 0 4 Exhaust venting method chimney Fume ducting diameter mm 126 Exhaust gas te...

Page 32: ...mption m3 h 1 13 Maximum gas consumption kg h 1 9 Minimum gas consumption kg h 0 8 NOx classification 3 Gas pressure Inlet pressure mbar 20 37 Membrane diameter mm 5 95 4 20 Maximum pressure in discha...

Page 33: ...e range C 38 60 Electrical data Voltage frequency V Hz 230 50 Consumption W 147 Electrical casings IPX4D Current A 0 4 Exhaust venting method turbo Fume ducting diameter mm 60 100 80 125 80 80 Exhaust...

Page 34: ......

Page 35: ......

Page 36: ...www protherm eu P 2 _ G E P A R D _ u s e r m a n u a l _ w o r k b a s i s _ E N _ 0 2 0 2 1 0 Insert the bar code Protherm spol s r o Pplk P ju a 45 909 01 Skalica Tel 034 6966 101 fax 034 6966 111...

Reviews: