NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO 

A FUEL SOURCE

© 2018 Pinnacle Climate Technologies, Inc. 

Cabinet Heater User's Manual

7

®

OPERATION

Propane Supply / Information:

Propane (LP)

This heater is not supplied with a propane cylinder. Use 

only an approved propane cylinder.

LP Characteristics

 

– Flammable, explosive under pressure, heavier than 

air and pools in low areas.

 

– In its natural state, propane has no odor, but for 

your safety an odor that smells like rotten cabbage 

has been added.

 

– Contact of propane (LP) gas with the skin can cause 

freeze burns.

 

– Heater is manufactured for use with propane gas 

only. DO NOT attempt to convert to any other gas. 

Such modifications are dangerous and will void the 

warranty.

 

– When heater is not in use, LP Cylinder must be 

turned OFF.

 

– Be sure that the LP Cylinder is located on a level 

and stable surface.

 

– DO NOT use this heater in a basement or below 

ground level. Propane is heavier than air and will 

always seek the lowest level. If you suspect a leak, 

shut off the valve at the LP Cylinder immediately.

The Propane (LP) cylinder must also be equipped with 

the following:

 

– A collar to protect the gas valve.

 

– A shut-off valve terminating a LP cylinder valve 

outlet as specified in the American National 

Standard for Compressed Gas Cylinder Valve Outlets 

and Inlets Connections.

 

– A safety relief valve having direct communications 

with the vapor space of the LP cylinder.

 

– The heater must operate on vapor withdrawal from 

the operating cylinder.

 

– Always keep LP cylinder fastened and upright.

 

– Avoid tipping the LP cylinder on its side when 

connected to a regulator, since this may cause 

damage to diaphragm in the regulator.

 

– Handle valves with care.

 

– Never connect an unregulated LP cylinder to a 

construction heater.

 

– DO NOT subject LP cylinder to excessive heat.

 

– Tightly close the gas shutoff valve on the LP 

cylinder after each use. 

 

– All fittings must be protected when disconnected 

from the LP cylinder.

 

– Never store an LP cylinder inside a building or in 

the vicinity of an gas burning appliances.

Pre-Lighting Instructions:

Connecting the LP Cylinder

ALL NEW LP CYLINDERS MUST BE PURGED 

BEFORE THE FIRST FILLING.

 

– Turn heater gas valve knob and LP cylinder valve to 

OFF position.

 

– LP cylinder valve equipped with old style fitting 

has LEFT HANDED THREADS. Turn fitting 

CLOCKWISE to loosen. Protect this fitting when 

disconnected from LP cylinder.

 

– Have your LP cylinder filled by your local propane 

gas supplier.

 

– Some LP cylinders have a bleed-OFF valve. This 

valve should be inspected for leaks after each 

filling of the LP cylinder. Turn the valve clockwise 

to close.

 

– Fasten full propane tank and connect proper 

fitting to LP cylinder valve by turning COUNTER-

CLOCKWISE.

 

– With heater gas valve knob still in OFF position 

turn ON the LP cylinder valve and check for leaks 

with soap solution.

Propane is safe to 

use when properly 

handled. Careless 

handling of the LP cylinder could result in a 

fire and or an explosion.

CAUTION

The disconnected 

tank must never 

be stored in a 

building, garage or any other enclosed area.

CAUTION

Purging and 

filling of the LP 

cylinders must 

be performed by personnel who have been 

thoroughly trained in accepted LP gas 

industry procedures. Failure to follow these 

instructions may result in explosion, fire, 

severe personal injury or death. 

WARNING

Summary of Contents for PT-18-PCH-A

Page 1: ...CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLA TILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOL...

Page 2: ...s product can expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings...

Page 3: ...OOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of ou...

Page 4: ...y Do not convert to any other gas Installation must conform to local codes or in their absence with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natural...

Page 5: ...ment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage If the heater is damaged promptly...

Page 6: ...hose and regulator assembly supplied 1 Remove the back cover by sliding the cover straight up and away from the heater body Place the LP cylinder on the bottom plate and replace the back cover 2 To co...

Page 7: ...ipping the LP cylinder on its side when connected to a regulator since this may cause damage to diaphragm in the regulator Handle valves with care Never connect an unregulated LP cylinder to a constru...

Page 8: ...on Keep gasoline and any other flammable liquids away from the heater WARNING Lighting Instructions 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder...

Page 9: ...rakes push the lever down on each wheel To move the heater release the brakes simply by flipping the levers on both brakes up OPERATION CONT Risk of indoor air pollution and Carbon Monoxide Poisoning...

Page 10: ...th your heater and re package the heater using these materials for safe storage Debris dust and dirt inside of the heater body can affect the performance of your heater This de bris can impair the hea...

Page 11: ...der valve Wait 1 min for switch to click off Reopen LP cylinder valve slowly 7 Move heater to a level surface No spark created when ignited 1 Incorrect igniter electrode position 2 Electrode damaged o...

Page 12: ...POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2018 Pinnacle Climate Technologies Inc Cabinet Heater User s Manual 12 1 2 3 EXPLODED VIEW PARTS LIST Item Description PT 18 PCH A 1 Front Castor 50 01...

Page 13: ...he item freight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 641 6996 Fax 320 251 2922 Web www protemp us Email info pinnacleclimate com 2018 Pinnacle Climate Technologies Inc...

Page 15: ...E CARTON UNE DISTANCE S CURITAIRE DE LA CHAUFFERETTE COMME RECOMMAND DANS LES PR SENTES INSTRUCTIONS NE JAMAIS UTILISER LA CHAUFFERETTE DANS DES ENDROITS QUI CONTIENNENT OU POURRAIENT CONTENIR DES MAT...

Page 16: ...tte Ce produit peut vous exposer des produits chimiques notamment du plomb reconnus dans l tat de Californie comme cause de cancer de malformations cong nitales ou d autres troubles de la reproduction...

Page 17: ...e temporaire des structures ou des b timents bien ventil s en cours de construction de modification ou de r paration Une ouverture d un minimum de 2 800 cm sur l air ext rieur doit exister pour chaque...

Page 18: ...vertir pour un autre gaz L installation doit tre conforme aux codes locaux ou en leur absence avec la norme du Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 et du Code d installation...

Page 19: ...uchons en plastique attach s l ensemble connecteur d entr e et tuyau r gulateur pour l entreposage 2 Enlever tous les articles du carton 3 V rifier qu aucun article n a t endommag pendant le transport...

Page 20: ...u et de r gulateur fourni 1 Ouvrir le capot arri re en le glissant vers le haut hors du bo tier de la chaufferette Placer la bouteille de propane sur la plaque inf rieure et replacer le capot arri re...

Page 21: ...mager le diaphragme l int rieur du r gulateur Manipuler les robinets avec pr caution Ne jamais raccorder une bouteille de propane sans r gulateur une chaufferette de construction NE PAS soumettre la b...

Page 22: ...e inflammable loin de la chaufferette Instructions d allumage 1 ARR TER Lire toutes les consignes de s curit fournies avec cette chaufferette 2 Tourner le robinet de la bouteille de propane dans le se...

Page 23: ...freins appuyer sur le levier de chaque roulette Pour d placer la chaufferette rel cher les freins en relevant simplement le levier des deux roulettes MODE D EMPLOI SUITE Risque de pollution de l air i...

Page 24: ...t s r Les d bris la poussi re et les salet s l int rieur du bo tier de la chaufferette peuvent nuire son rendement De tels d bris peuvent r duire la capacit de l appareil aspirer de l air pour la vent...

Page 25: ...de la bouteille de GPL Attendre une minute que l interrupteur s ouvre Rouvrir le robinet de la bouteille 7 Replacer l appareil sur une surface plane Aucune tincelle produite lors de l allumage 1 Posi...

Page 26: ...D ALIMENTATION OU DE COMBUSTIBLE 2018 Pinnacle Climate Technologies Inc Manuel de l utilisateur de la chaufferette cabinet 12 MD 1 2 3 VUE CLAT E LISTE DES PI CES No de r f Description PT 18 PCH A 1...

Page 27: ...icle en question et d terminera s il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l ar...

Page 28: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Num ro sans frais 800 641 6996 T l copieur 320 251 2922 Web www protemp us Courriel info pinnacleclimate com 2018 Pinnacle Climate Technologies Inc...

Page 29: ...T N A UNA DISTANCIA PRUDENTE DEL CALENTADOR SEG N LO RECOMIENDAN ESTAS INSTRUCCIONES NUNCA USE EL CALENTADOR EN ESPACIOS QUE CONTENGAN O PUEDAN CONTENER COMBUSTIBLES VOL TILES O SUSPENDIDOS EN EL AIRE...

Page 30: ...omo conocidas en el estado de California como causantes de c ncer y defectos de nacimiento u otros da os reproductivos Si desea m s informaci n visite www P65Warnings ca gov EXTREMADAMENTE CALIENTE CU...

Page 31: ...ral de edificios adecuadamente ventilados o estructuras en construcci n modificaci n o reparaci n Proporcione una abertura de al menos tres pies cuadrados 0 28 m2 al aire exterior por cada 100 000 BTU...

Page 32: ...ierta a ning n otro gas La instalaci n debe cumplir con los c digos locales o a falta de ellos con la norma para el almacenamiento y la manipulaci n de gases licuados de petr leo ANSI NFPA 58 y el C d...

Page 33: ...ector de entrada y en el conjunto del regulador y manguera cuando almacene la unidad 2 Retire todos los art culos de la caja de env o 3 Inspeccione todos los art culos por si tuvieran da os por el env...

Page 34: ...unto del regulador suministrado 1 Retire la cubierta trasera desliz ndola en l nea recta hacia arriba y alej ndola del cuerpo del calentador Coloque el tanque de LP en la placa base y vuelva a colocar...

Page 35: ...nectado a un regulador ya que eso podr a causar da o al diafragma en el regulador Trate las v lvulas con cuidado Nunca conecte un tanque de LP no regulado en un calentador para construcci n NO someta...

Page 36: ...dor lejos de gasolina y otros l quidos inflamables Instrucciones de encendido 1 ALTO Lea toda la informaci n de seguridad que acompa a a este calentador 2 Gire la v lvula del tanque de propano HACIA L...

Page 37: ...frenos empuje la palanca hacia abajo en cada rueda Para mover el calentador suelte los frenos simplemente moviendo hacia arriba las palancas en ambos frenos FUNCIONAMIENTO CONTIN A Riesgo de contamin...

Page 38: ...materiales para su almacenamiento seguro Los residuos el polvo y la mugre dentro del cuerpo del calentador pueden afectar el rendimiento de su calentador Estos residuos pueden perjudicar la capacidad...

Page 39: ...o para que el interruptor haga clic Abra de nuevo y lentamente la v lvula del cilindro de LP 7 Mueva el calentador a una superficie nivelada No se gener la chispa cuando se encendi 1 Posici n incorrec...

Page 40: ...DE ALIMENTACI N O A UNA FUENTE DE COMBUSTIBLE 2018 Pinnacle Climate Technologies Inc Manual del usuario del calentador gabinete 12 1 2 3 VISTA DETALLADA LISTA DE PIEZAS Pieza Descripci n PT 18 PCH A...

Page 41: ...o Si Pinnacle Climate Technologies Inc descubre que el art culo est en condiciones normales de funcionamiento o que no est defectuoso se devolver el art culo con el flete por cobrar Esta Garant a Limi...

Page 42: ...Industrial Blvd 101 Sauk Rapids MN 56379 USA Llamada sin costo 800 641 6996 Fax 320 251 2922 Sitio web www protemp us Correo electr nico info pinnacleclimate com 2018 Pinnacle Climate Technologies In...

Reviews: