6.3.3.12
EVENt subsystem
Command
Parameter
Status after
Factory Reset
Remarks
:COUNt?
Query only. Response
format is:
<n>
n : total number of events
recorded in the log
:CLEAr
No Query. Clears the
entire event log.
:VIEW?
n
n = 0 to max event count
Query only. Response
format is:
<id number, “tds”, “info”>
id number : identification
number for the recorded
event type
tds: time and date stamp
for the event in the
format “yyyy-mm-dd,
hh:mm:ss”
info: Supplementary text
string describing the
event type
6.3.3.13
TEST subsystem
Command
Parameter
Status after
Factory Reset
Remarks
:ENABle
OFF | SCARrier | M1Carrier |
M50Carrier | TSSTuffing
OFF
:M1Carrier
1 to 1705
1
-1 carrier in 2k mode.
1 to 6817
1
-1 carrier in 8k mode.
:M50Carrier
1 to 1705
1
-50 carrier in 2k mode.
1 to 6817
1
-50 carrier in 8k mode.
6.3.3.14
FACTory subsystem
Command
Parameter
Status after
Factory Reset
Remarks
:SNINst?
<Instrument Serial No>
:SNXAcboard?
<XA Serial No>
:MONitor
:LIMits?
“MC_BT” | “MC_025V” |
“MC_033V” | “MC_050V” |
“MC_120V” ,
<lower limit>,
<upper limit>
Format for query
command:
:FACT:MON:LIM?
“MC_BT”
:MONitor
:CURRent?
“MC_BT” | “MC_025V” |
“MC_033V” | “MC_050V” |
“MC_120V”
Query only.