b) Optionally attach retractable type fall arrester to side attachment point on
the head.
c) Pull out tripod legs to a desired length and lock them using locking cotter
bolts.
Adjust length of legs so the head is located horizontally.
Legs must be of the same length at all times.
d) Automatic pin is equipped with locking fins which are unlocked by button in
the handle. The pin must be pushed in completely in order to lock the fins
correctly.
3/5
e) Correctly locked automatic pin.
f) Secure tripod legs against accidental moving apart with a chain. Chain ends
must be connected with carabiner.
The chain should be well tensioned between tripod legs. If necessary remove
any excess clearance. Instead of chain, special strip (delivered with tripod) can
be used.
g) Optionally it is possible to install steps AT013-300 allowing for easy access to
the device head during installation of work rope. Steps are installed by pushing
cotter bolt in inner leg adjustment holes.
h) For tripod TM15 it is recommended to use at least 4 steps AT013-300.
i) To fold the tripod, remove steps, pull out cotter bolts and fold the legs.
10. INSTALLATION OF WORK ROPE OF DEVICE INSTALLED ON TRIPOD LEG
a) During installation of work rope on the tripod head it is possible to enter the
tripod leg using steps AT013-300. When using steps it is advisable to use
additional devices as retractable type fall arrester.