![Protekt RJ200 Instruction Manual Download Page 15](http://html.mh-extra.com/html/protekt/rj200/rj200_instruction-manual_1620060015.webp)
DAVIT
INSTRUCTION MANUAL
EN 795:2012 Class B
Reference number:
RJ200
BEFORE USE READ THIS MANUAL CAREFULLY
edition: 3/25.02.2019 pl
p. 15
2. Insert four legs “3” into previously levelled base “1” and lock them with four pins
“10” and push cotters at the end.
3. Using forklift truck place three concrete unit weights (RJ200.10.000) with a
weight of 1000kg each on base “1” or fix beams “7” to four legs “3” with bolts M12
delivered in the set. On base “1” place OSB bottom panel “8” and then four OSB
side panels “9”.
4. Fix socket “5” in cover “4” to marker.
5. Using forklift truck fix cover “4” with previously installed socket “5” on legs “3” and
lock it with four pins “10” and push cotters at the end.
6. Fill the case with ballast with a total weight of min. 3000kg (not applicable if
concrete unit weights are used).
7. Push arm “6” in to socket “5” to marker. To perform this operation use a crane or
other lifting device, e.g. mobile crane. Lift the frame in marked points. Before that
lock possibility of automatic arm rotation by attaching line for lowering of snap hook
of retractable type fall arrester to cover “4”.
Miejsca montażu zawiesi do transportu
pionowego ramienia
Points for installation of slings for lifting of
the arm
WIDOK A
VIEW A
WIDOK B
VIEW B