![Protekt AZ411 Use And Instruction Manual Download Page 3](http://html.mh-extra.com/html/protekt/az411/az411_use-and-instruction-manual_1620048003.webp)
Polski Rejestr Statków S.A. al. gen. Józefa Hallera 126, 80-
416 Gdańsk, Poland
According to European standard EN365:2004 and EN795:2012 type B a requirement to check the legibility of the product
PROTEKT Grzegorz Łaszkiewicz ul.Starorudzka 9 93
-
403 Łódź
5. Device marking
7. Installation of device
KEY:
Serial number
Date of manufacture
Number of users – max. 3
Three acceptable methods of installation are given in Figure 1
The device is equipped with fall indicator which deforms, breaks, bends if
the device is affected by an instantaneous force of 3–4kN. If the fall indicator
is damaged or shows any signs of deformation, it can be presumed that the
device has been used to arrest a fall.
Figure 3.
Method of device marking
6. Installation of anchor point
Before anchor point AZ411 is installed, it must be stored in a place which is:
clean, free from any vapours of corrosive substances, and in conditions
preventing its mechanical damage. Also please take into account
environmental conditions present in the place of installation which may
cause corrosion of anchor point and fasteners.
- Installation of anchor point must be carried out by a properly qualified and
skilled person familiarized with the instruction manual.
- Follow general rules for use of personal fall protection equipment in
accordance with EN 795:2012,
- Example installations are shown in Figure 1
Figure 4. Fall indicator
8. Essential principles of use of personal fall protection equipment
- Anchor point AZ411 must be used in accordance with instruction manuals
for personal fall protection equipment and standards:
EN 361 - for full body harnesses
EN 352-3; EN 355; EN 360 - for fall restraint devices
EN 362 - for connectors
EN 795 - for anchor points
- personal fall protection equipment should be used only by personnel
trained in its use.