background image

1

WARNING:

 This product is part of a personal 

fall arrest system. The user must read and 

follow the manufacturer’s instructions for each 

component or part of the complete system. 

These instructions must be provided to the 

user of this equipment. The user must read and 

understand these instructions or have them 

explained to them before using this equipment. 

Manufacturer’s instructions must be followed 

for proper use and maintenance of this product. 

Alterations or misuse of this product or failure to 

follow instructions may result in serious injury or 

death.

IMPORTANT:

 If you have questions on the use, 

care, or suitability of this equipment for your 

application, contact Capital Safety.

IMPORTANT:

 Record the product identi

fi

 cation 

information from the ID label in the inspection 

and maintenance log in section 9.0 of this 

manual.

1.0 APPLICATIONS

1.1 PURPOSE: 

The Protecta

®

 Standing Seam Roof Anchor (Figure 1) is designed for use as an anchorage 

connector for a personal fall arrest system on sloped or 

fl

 at standing seam roofs, with seam spacing from 

12 inches (30 cm) to 24 inches (61 cm). The Standing Seam Roof Anchor is designed for use with the 

Protecta Rebel™ SRL (models 3590500 an 3590550) and other Self Retracting Lifelines (SRLs) that limit 

arresting forces to 1,800 pounds (8 kN) only. It is especially suited for applications where falls may occur 

over an edge (roo

fi

 ng, leading edge construction, etc.) if used with an SRL intended for leading edge work 

(e.g., the 3590540 Protecta Rebel/3504500 DBI-SALA Ultra-Lok Leading Edge Self Retracting Lifeline).

1.2 LIMITATIONS: 

Consider the following application limitations before using this equipment:

IMPORTANT:

 This anchor shall be installed and used under the supervision of a Quali

fi

 ed Person

1

 as part 

of a complete personal fall arrest system that maintains a safety factor of at least two.

1

 

 A. ROOF 

PANELS: 

The Standing Seam Roof Anchor must only be used on structural standing seam roof 

panels that meet the geometric and load requirements specified in section 2.0. Refer to Table 1 for a list 

of compatible roof panels.

 B. CAPACITY:

 The Standing Seam Roof Anchor is designed for use by persons with a combined weight 

(clothing, tools, etc.) of no more than 420 lbs (190 kg). No more than one personal fall arrest system 

may be connected to this equipment at one time.

 C. FREE 

FALL: 

Personal fall arrest systems used with this equipment must be rigged to limit the free fall to 

six feet or less. See the personal fall arrest system manufacturer’s instructions for more information.

1 Quali

fi

 ed Person: An individual with a recognized degree or professional certi

fi

 cate, and extensive knowledge and experience 

in the subject 

fi

 eld, who is capable of design, analysis, evaluation, and speci

fi

 cation in the subject work, project, or product. 

Refer to OSHA 1910.66, 1926.32, and 1926.502.

Figure 1 - Standing Seam Roof Anchor

Seam Clamp

SRL Swivel

Bracket

Adjustable Leg

Assembly

Load Bar

Clamping Plate

© Copyright 2016, Capital Safety.

Instructions for the following series products:

Standing Seam Roof Anchor

Model Number: 2190001

USER INSTRUCTION MANUAL

STANDING SEAM ROOF ANCHOR

This manual is intended to meet the Manufacturer’s Instructions, and should be used as part of 

an employee training program as required by OSHA.

Form: 5902435  Rev: D

Trusted Quality Fall Protection

Summary of Contents for Standing Seam Roof Anchor

Page 1: ...ine 1 2 LIMITATIONS Consider the following application limitations before using this equipment IMPORTANT This anchor shall be installed and used under the supervision of a Qualified Person1 as part of a complete personal fall arrest system that maintains a safety factor of at least two 1 A ROOF PANELS The Standing Seam Roof Anchor must only be used on structural standing seam roof panels that meet...

Page 2: ...plication and use See section 4 0 1 3 APPLICABLE STANDARDS Refer to applicable standards including local state and federal requirements for more information on personal fall arrest systems and associated components 2 0 SYSTEM REQUIREMENTS 2 1 COMPATIBILITY OF COMPONENTS Protecta equipment is designed for use with Capital Safety approved components and subsystems only Substitutions or replacements ...

Page 3: ... manner that does not allow the connector to align properly while under load 2 4 PERSONAL FALL ARREST SYSTEM Personal fall arrest systems used with this equipment must meet applicable state federal and OSHA requirements A full body harness and Self Retracting Lifeline must be used with the Standing Seam Roof Anchor The personal fall arrest system must limit fall arrest forces to 1 800 lbs 8 kN The...

Page 4: ...ffect a worker s ability to withstand falls Pregnant women and minors must not use this equipment 3 1 BEFORE EACH USE OF THIS EQUIPMENT INSPECT ACCORDING TO SECTION 5 0 OF THIS MANUAL 3 2 PLAN YOUR SYSTEM BEFORE INSTALLATION CONSIDER ALL FACTORS THAT WILL AFFECT YOUR SAFETY DURING USE OF THIS EQUIPMENT CONSIDER THE FOLLOWING WHEN PLANNING YOUR SYSTEM A ANCHORAGE Select an anchorage that meets the ...

Page 5: ...The SRL must be secured in the swivel bracket with the included 5 8 inch bolt Figure 8 The bolt should pass through the holes in the swivel bracket and the anchor point e g swivel eye on the SRL Do not substitute hardware other than provided with the standing seam anchor If the bolt will not fit through the designated anchor point on the SRL or if the SRL does not fit within the swivel bracket the...

Page 6: ... of the consequences of improper installation or use of this equipment This user manual is not a substitute for a comprehensive training program Training must be provided on a periodic basis to ensure proficiency of the users WARNING Training must be conducted without exposing the trainee to a fall hazard Training should be repeated on a periodic basis 5 0 INSPECTION 5 1 FREQUENCY BEFORE EACH USE ...

Page 7: ... clamp plate and seam clamp fasteners to the torque requirements stated in Figure 8 Step 5 Inspect the self retracting lifeline and the full body harness according to the manufacturer s user instruction manuals 5 3 If the inspection reveals an unsafe or defective condition remove the Standing Seam Roof Anchor from service and destroy or return it to an authorized service center for repair IMPORTAN...

Page 8: ... 24 ga steel NCI Midwest Metallic Ultra Dek 24 ga steel Ceco CXP 22 ga steel New Tech Machinery S5 5500 Snap Lock 1 1 2 24 ga steel Ceco CXP 24 ga steel New Tech Machinery SS675 Sanp Lock 1 3 4 24 ga steel Central States Manufacturing Central Loc 22 ga steel Petersen Aluminum Corp Snap Clad 22 ga steel Central States Manufacturing Central Loc 22 ga steel Petersen Aluminum Corp Snap Clad 24 ga stee...

Page 9: ...9 8 0 LABELING 8 1 THESE LABELS MUST BE PRESENT AND FULLY LEGIBLE Warning Label ID Label ...

Page 10: ...SE INSPECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By ...

Page 11: ...SE INSPECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By ...

Page 12: ... dba CAPITAL SAFETY USA CAPITAL SAFETY warrants to the original end user End User that its products are free from defects in materials and workmanship under normal use and service This warranty extends for the lifetime of the product from the date the product is purchased by the End User in new and unused condition from a CAPITAL SAFETY authorized distributor CAPITAL SAFETY S entire liability to E...

Reviews: