1
WARNING:
This product is part of a personal
fall arrest system. The user must read and
follow the manufacturer’s instructions for each
component or part of the complete system.
These instructions must be provided to the
user of this equipment. The user must read and
understand these instructions or have them
explained to them before using this equipment.
Manufacturer’s instructions must be followed
for proper use and maintenance of this product.
Alterations or misuse of this product or failure to
follow instructions may result in serious injury or
death.
IMPORTANT:
If you have questions on the use,
care, or suitability of this equipment for your
application, contact Capital Safety.
IMPORTANT:
Record the product identi
fi
cation
information from the ID label in the inspection
and maintenance log in section 9.0 of this
manual.
1.0 APPLICATIONS
1.1 PURPOSE:
The Protecta
®
Standing Seam Roof Anchor (Figure 1) is designed for use as an anchorage
connector for a personal fall arrest system on sloped or
fl
at standing seam roofs, with seam spacing from
12 inches (30 cm) to 24 inches (61 cm). The Standing Seam Roof Anchor is designed for use with the
Protecta Rebel™ SRL (models 3590500 an 3590550) and other Self Retracting Lifelines (SRLs) that limit
arresting forces to 1,800 pounds (8 kN) only. It is especially suited for applications where falls may occur
over an edge (roo
fi
ng, leading edge construction, etc.) if used with an SRL intended for leading edge work
(e.g., the 3590540 Protecta Rebel/3504500 DBI-SALA Ultra-Lok Leading Edge Self Retracting Lifeline).
1.2 LIMITATIONS:
Consider the following application limitations before using this equipment:
IMPORTANT:
This anchor shall be installed and used under the supervision of a Quali
fi
ed Person
1
as part
of a complete personal fall arrest system that maintains a safety factor of at least two.
1
A. ROOF
PANELS:
The Standing Seam Roof Anchor must only be used on structural standing seam roof
panels that meet the geometric and load requirements specified in section 2.0. Refer to Table 1 for a list
of compatible roof panels.
B. CAPACITY:
The Standing Seam Roof Anchor is designed for use by persons with a combined weight
(clothing, tools, etc.) of no more than 420 lbs (190 kg). No more than one personal fall arrest system
may be connected to this equipment at one time.
C. FREE
FALL:
Personal fall arrest systems used with this equipment must be rigged to limit the free fall to
six feet or less. See the personal fall arrest system manufacturer’s instructions for more information.
1 Quali
fi
ed Person: An individual with a recognized degree or professional certi
fi
cate, and extensive knowledge and experience
in the subject
fi
eld, who is capable of design, analysis, evaluation, and speci
fi
cation in the subject work, project, or product.
Refer to OSHA 1910.66, 1926.32, and 1926.502.
Figure 1 - Standing Seam Roof Anchor
Seam Clamp
SRL Swivel
Bracket
Adjustable Leg
Assembly
Load Bar
Clamping Plate
© Copyright 2016, Capital Safety.
Instructions for the following series products:
Standing Seam Roof Anchor
Model Number: 2190001
USER INSTRUCTION MANUAL
STANDING SEAM ROOF ANCHOR
This manual is intended to meet the Manufacturer’s Instructions, and should be used as part of
an employee training program as required by OSHA.
Form: 5902435 Rev: D
Trusted Quality Fall Protection