93-340-74 Issue 5                         CirrusPro Locator Operating Manual                             Page 3 of 12 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0  General Safety Rules  

 

2.0  Cirrus Pro Locator 

 

The Cirrus Pro Locator is the next generation of portable air sampling detector. Belonging to the Pro 
Series family, the Fire detector uses 

Cloud Chamber Detection 

technology for very early warning fire 

detection. The unit can identify the source and take you within one foot of an invisible and odourless 
fire in a 20,000 sq. ft room. The fire locator features adjustable sensitivity levels that can guide you in 
the right direction. Because it uses 

Cloud Chamber Detection

 you don’t have to worry about the device 

giving  you  false  information;  it  is  immune  to  dust,  heat,  cold,  humidity  and  other  factors  that  could 
deter it from leading you to the right location.

 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

CAUTION:  Carefully  read  through  this 
entire  manual  before  using  your  new 
Cirrus Pro Locator. 
 
Personal  Safety:  Stay  alert,  watch  what 
you  are  doing  and  use  common  sense 
when operating the fire detector. 
 
Do  not  operate  the  unit  in  areas  with 
heavy smoke concentrations. 
 
Do  not  operate  the  unit  while  standing  in 
water. 

Servicing must be performed only by  
Protec Fire Detection plc. 

 

Charge the battery only with the specified 
charger for the battery. 

 

Do not overreach when operating the 
Pro Locator’s handheld probe. 

 

Keep correct footing and balance. 

 

Use only accessories that are 
recommended by the manufacturer. 

 

1 – Power Switch & Power LED 
 
2 – Charging/Fault LEDs 
 
3 – LCD Display 
 
4 – Sensitivity Adjustment Buttons 
 
5 – Handheld Sampling Probe 
 
6 – Pipe Inlet/Pipe Guard-Side Mount 
 
7 – DC Charger  
 
8 – Battery Charger (Included) 
 

 

ProSeries detectors can tell you which room,  

but only the ProLocator can tell you where in the room.

 

 

  Do not enter or sample in an area if either flames or smoke are present. 
 

 

Summary of Contents for Cirrus Pro Locator

Page 1: ...Protec Fire Detection Export Ltd Protec House Churchill Way Nelson Lancashire BB9 6RT Telephone 44 0 1282 717171 Fax 44 0 1282 717273 CIRRUS PRO LOCATOR OPERATING MANUAL...

Page 2: ...THE CIRRUS PRO LOCATOR 5 5 0 OPERATING PROCEDURE 6 5 1 After Localizing the Fire Threat 8 6 0 TESTING AND DEMONSTRATING THE PRO LOCATOR 8 7 0 LCD MONITORING AND CONTROL 9 7 1 Standard Operation 9 7 2...

Page 3: ...n CAUTION Carefully read through this entire manual before using your new Cirrus Pro Locator Personal Safety Stay alert watch what you are doing and use common sense when operating the fire detector D...

Page 4: ...ge is 100V 240V AC 50 60Hz Only use approved charger Preparing your Cirrus PRO Locator Press the Power Button to turn unit on The power light will illuminate green The unit will initialise if the FAUL...

Page 5: ...graph on the display and four audible indicator tone speeds in conjunction with 10 selectable sensitivity settings As you get closer to the fire threat the percentage will increase and the audible ind...

Page 6: ...hich half of the area has a greater concentration of combustion 4 While slowly walking through the area watch bar graph level and audible indicator will increase or decrease according to how close you...

Page 7: ...with this divide and sample approach until you isolate the area down to a single room 8 When sampling in smaller areas there will be a higher concentration of combustion You may need to greatly decre...

Page 8: ...wire to simulate the overheating condition of a fire threat 1 Be sure you fully understand How to Use the Pro Locator Section 4 0 and the Operating Procedures Section 5 0 prior to any testing or demon...

Page 9: ...for the unit to describe the actual fault This is achieved by entering the engineer menu please refer to section 7 5 In the event of the water running out the LCD will display and the fault LED will i...

Page 10: ...urs 30mins 30min Count down from 5minutes NOTE if the batteries have NOT been FULLY charged these do NOT use the estimates Once all the battery cells are empty a 5 minutes count down will start and th...

Page 11: ...the error persists then replace the geartray assembly Processor Fault This is indicated if a problem has been detected with micro controller or the Read Only Memory ROM This is a serious failure and...

Page 12: ...it weekly 10 0 Technical Specifications Dimensions WxHxD 13 75 x 10 25 x 4 75 350 x 260 x 120mm Weight Standard 13 2 lbs 6 kg Extended battery life 15 4 lbs 7 kg Power 24v DC Two 12V 2 2 or 3 3 Ah SLA...

Reviews: