APPENDIX: ALARM CODE TABLE 

Code 

Descriptions 

Emergency Method 

F001 

No enough refrigerant in cleaning 
tank 

Supply refrigerant in time. 

F002 

Too much refrigerant in tank 

Transfer some refrigerant to another tank. 

F003 

High pressure 

Stop use for a period. 

F004 

No refrigerant to recovery 

Run next function. 

F005 

Cannot vacuum 

Recovery first and then run vacuum. 

F006 

Exchange dry-filter 

The dry-filter is life-end. 

F007 

Vacuum pump maintenance 

Change the pump oil in time. 

F009 

No enough refrigerant in recharging 
tank 

Change a new tank of refrigerant. 

F010 

Prohibit changing the recharging 
tank 

Here has enough refrigerant in the tank. 

ERR1 

Load cell calibration error at step 1 

Check if the scale pan empty. 

Check the connection of signal cable being ok. 
Check if the load cell is damaged. 

ERR2 

Load cell calibration error at step 2 

Check if the weight has been put onto the 
scale pan. 

Check the connection of signal cable being ok. 
Check if the load cell is damaged. 

 

Summary of Contents for AC-200A

Page 1: ...AC 200AA C System Maintenance Centre AC 200A A C System Maintenance Centre...

Page 2: ...of the machine Keep away from moving parts and rotating elements such as cooling fans alternators and heating components etc to avoid harm Wear protective clothing gloves and goggles As automotive air...

Page 3: ...y functions 2 3 Operation 3 1 Parts descriptions 3 2 First use 4 3 Recovery Recycling 4 4 Preparations before Flushing 5 5 Flushing Recovery 5 6 Vacuum 6 7 New oil adding 6 8 Recharging 6 9 Refrigeran...

Page 4: ...easy and fouling to restore the A C system performance B With forward flushing reverse flushing and pulse flushing functions which greatly improve the cleaning effect C Using large size glass tube wit...

Page 5: ...Recovery Recycling C Used oil discharging D Vacuum E New oil filling F Recharging 2 Subsidiary functions A Refrigerant supplying B Load cell calibration C Recharging tank exchanging procedure D Mainte...

Page 6: ...il adding New oil bottle Parameter decrease key Parameter increase key Enter key Flushing key Min indicator Kg indicator LED displayer Recovery key Filling key Start key Switch for used oil discharge...

Page 7: ...ank 2nd Open the valve of the refrigerant tank and place it upside down on the load cell pan 3rd Fix it with the accessories Note If you need not using the auxiliary load cell please fix it as the man...

Page 8: ...ocess Otherwise it easily causes damages to the air conditioning and risk of accident C Press key to select the Recovery Flushing function D The LED displays the flushing time E Set the flushing time...

Page 9: ...ys code as F00 during the process please refer to the APPENDIX ALARM CODE TABLE 7 New oil adding A Pour new oil into the new oil bottle Note add new oil more 20ml than the used oil drained out to avoi...

Page 10: ...is kg D Presses START key to run E Stop automatically after recharging finished Note In the filling process if LED displays alternately the remaining amount of filling and the letters AC it means tha...

Page 11: ...of external tank iv After finished disconnect the pipes and re back the cap to the auxiliary port 11 Maintenance A Calibration of load cell When the load cell is not precise it needs to be calibrated...

Page 12: ...the LED displays F008 the vacuum pump oil must be changed ii Step 1 unscrew the block of the drain port to drain entirely out the old oil Then re back the block to the drain port iii Step 2 unscrew th...

Page 13: ...ory C 2 Set the recharging tank external tank as default viii Press ENTER to save ix Power off B Parameter inquiring i Press and hold Recharging key to enter parameter inquiring mode ii In this mode f...

Page 14: ...lue according to the ID pasted on the dry filter Only you set the correct 4 digits the equipment can accept it Note The code used already will be not able to be accepted again vi Code CON total times...

Page 15: ...06 Exchange dry filter The dry filter is life end F007 Vacuum pump maintenance Change the pump oil in time F009 No enough refrigerant in recharging tank Change a new tank of refrigerant F010 Prohibit...

Reviews: