Model:  PC-NVI-270/320 

 
 
 
 
 
 
 
 

 

 

Summary of Contents for PC-NVI-110

Page 1: ...Models PC NVI 90 PC NVI 110 PC NVI 140 PC NVI 170 PC NVI 210 PC NVI 230 PC NVI 270 PC NVI 320 Installation and Operation Manual PROTEAM EUROPA Swimming Pool Heat Pump ...

Page 2: ... pool and extending your swimming season The Proteam Inverter Heat Pump is a smart heat pump which knows how to heat your pool and maintain its temperature in the most efficient way thanks to the full inverter technology Please read the manual carefully to get the maximum benefitfromyourheatpump Please read carefully ...

Page 3: ...2 PARAMETER CHECKING AND ADUSTMENT 12 Parameter list 13 Malfunctioning of the unit and maintenance 13 MAINTAINING THE UNIT 16 Cleaning the pipe system in the heat exchanger 17 Cleaning the air system 17 Winter Shutdown Lay up 17 TROUBLESHOOTING 17 ENVIRONMENTAL INFORMATION 18 DISPOSAL REQUIREMENTS 18 WIRING DIAGRAM 19 Specification 21 READ THIS MANUAL CAREFULLY BEFORE STARTING UP THE UNIT DO NOT T...

Page 4: ...functions are available Auto operation Auto restart Auto defrost Timer on off no human input required Wide temperature operating range 10 C to 46 C Reliable operation To ensure maximum performance and reliability of the unit multiple protection devices have been built into the units including insufficient water flow protection high low pressure protection overload protection compressor protection ...

Page 5: ...capacityofthepowercircuitisinsufficientorthereisanincompleteelectricalcircuit itcouldresultin fire or electric shock Theunitmustalwayshaveanearthedconnection If the power supply is not earthed you must not connect the unit Neveruseanextensioncabletoconnecttheunittotheelectricpowersupply Ifthereisnosuitable earthedwallsocketavailable haveoneinstalledbyarecognizedelectrician Do not move repair the u...

Page 6: ...ngers or other objects into the fan or evaporator Thefanrunsathighspeed itcouldcause serious injury ITEMS INSIDE PRODUCT BOX Beforestartingtheinstallation pleasemakesurethatallpartsarefoundinsidethebox The UnitBox Item Image Quantity Proteam Inverter Swimming pool heat pump 1 Installation and Operation Manual 1 Water Connectors 50mm 2 Winter Cover 1 Anti vibration rubber feet 4 Water Drainage Pipe...

Page 7: ...5 OVERVIEW OF THE UNIT Unit Dimensions Model PC NVI 90 110 140 PC NVI 170 210 230 PC NVI 270 320 A 986 1076 1176 B 668 720 822 C 356 426 451 D 405 456 481 E 608 628 723 F 116 116 116 G 380 330 500 ...

Page 8: ... control components 17 Low pressure switch 5 Finheatexchanger 18 Power waterproof cover 6 Fan blade 19 Controller 7 Middle panel 20 Rightpanel 8 AC fanmotor 21 Needle valve 9 Fan 22 Four wayvalve 10 FrontPanel 23 High pressurevalve 11 Discharge grill 24 Electronic expansion valve 12 Reactance waterproof box 25 Titaniumtubeheatexchanger 13 Reactance 26 Balance tank ...

Page 9: ...oidpositioningheatpumponasurfacethatcantransmitvibrationstothe house Try to avoid placing appliance under a tree or exposed to water or mud which would probably make maintenance more difficult Waterconnection Theheat pumpisconnectedtoafiltrationcircuit withaby pass It isimperativethattheby pass is placedafterthepumpandthefilter The by passgenerallyconsistsof3valves This makes it possible to regula...

Page 10: ...s purpose the heat pump must be raised by at least 10 cm Howtoinstallthecondensatedrainkit 1 Install your heat pump by raising it by at least 10 cm using solid moisture resistant studs 2 Connect the exhaust hose to the drain hole located underneath the heat pump Hydraulic Connection ...

Page 11: ...gth of your cable is more than 10 meters we advise you to seek advice from a professional A voltage variation of 10 during operation is acceptable The power supply lines must be securely fastened The cable must be suitable for outdoor use The filter must be cleaned regularly to ensure that the water in the system is clean and to avoid any problems related to dirt or clogging of the filter Heat pum...

Page 12: ...wntooperatingthedigitalcontroller NEVER LET THE DIGITAL CONTROLLER GET WET THIS MAY CAUSE AN ELECTRIC SHOCK OR FIRE NEVER PRESS THE BUTTONS OF THE DIGITAL CONTROLLER WITH A HARD POINTED OBJECT THISMAYDAMAGETHEDIGITALCONTROLLER NEVERINSPECTORSERVICETHEDIGITALCONTROLLERYOURSELF ASKAQUALIFIED SERVICE PERSON TO DO THIS 1 Controller Instruction 1 1 General Input Voltage DC12V RS485 Communication Short ...

Page 13: ...mode Long Press to enter menu option Increase Temperatureset orpreviousscreen Decrease Temperature set or next screen Boost Runningmode Short presstoenter Smart Runningmode Short presstoenter Silent Runningmode Short presstoenter 2 2 Intructions for Display Symbols Heatingmode Cooling mode Auto runmode Boost mode Smartmode Silentmode wifi function when applicable HeatPumpoutputcapacityinrealtime W...

Page 14: ...30 seconds the controller will save the last setting and go back to original surface 3 3Set Parameter When heat pump is on Long press into memu displays Parameter Query press or select among Parameter Query Parameter Setting Debugging Status History Fault Short press to confirm your selction and switch to press or select displays the value When on status of Parameter Setting and display two 88 it ...

Page 15: ...17 Voltage Current 10 18 Standby 19 Standby 20 Standby 21 Fan speed Current 10 Malfunctioning of the unit and maintenance When anerror occurs or the protection mode is set automatically the circuit board and the wired controllerwillbothdisplaytheerrormessage Error Meaning Analysis Diagnosis Solution P01 Water Flow failure 1 No water flow 2 Flow switchfailure 3 Water systemblock 1 Check if water in...

Page 16: ...orrect 1 Repair leak and refill gas 2 Replace sensor P06 Outlet water temperature anti freezing protection 1 lower waterflow 2 heat exchanger blocked 3 Y shaped filter blocked 4 Overlow load 1 checkifthere is airin water system 2 Plateheatexchangerif blocked 3 checkifY shapedfilterhas block 4 check that design of indoor water system is appropriate if there is a water bypass 1 If there is a problem...

Page 17: ... Check sensor resistance valueorif sensoris faulty Re connect cable or change sensor E08 T6inletwater temperature sensor failure sensor temperature deviation or failure Check sensor resistance valueorif sensoris faulty Re connect cable or change sensor E09 T7outletwater temperature sensor failure sensor temperature deviation or failure Check sensor resistance valueorif sensoris faulty Re connect c...

Page 18: ...adjustment data E33 IPM adjustment data E34 AC input voltage abnormal E35 IPM adjustment data E36 Reserved E37 IPMmodule current frequency limits E38 IPMmodule voltage frequency limits E51 Failure of fan motor drive UNIT MAINTENANCE To protect the paintwork avoid leaning orputtingobjects on the unit The outer casing of the heat pump parts can be wiped with a damp cloth and domestic cleaner Warning...

Page 19: ...appens the ice must be removed in the vicinity of the air intake and exhaust air outlet grids toensure thattheminimumairflowrate ismaintained Winter Shutdown If there is a chance of freezing after the bathing season has ended when the swimming pool heating is switchedoffandtheexternaltemperatureisexpectedtodropbelowtheoperatinglimit thewatercircuit of theheat pump shouldbe completelydrained Otherw...

Page 20: ...ins R410A refrigerant inthe amount as stated in the specification Do not discharge R410A into the atmosphere R410A is a fluorinated greenhouse gas with a Global WarmingPotential GWP 1975 DISPOSALREQUIREMENTS Dismantlingoftheunit treatmentoftherefrigerant ofoilandofotherpartsmustbedoneinaccordance withrelevantlocalandnationallegislation Yourproductismarkedwiththissymbol Thismeansthatelectricalandel...

Page 21: ...19 Model PC NVI 90 110 140 170 210 230 SW1 1 SW1 2 Model OFF OFF OFF ON ON OFF ON ON ...

Page 22: ...20 Model PC NVI 270 320 ...

Page 23: ... 76 5 71 capacity kW Silent 2 98 4 07 5 33 6 50 COP Silent 6 67 6 53 6 53 6 47 Air35 Water28 Humidity 80 capacity kW 1 8 4 6 2 4 6 0 3 2 7 87 3 9 9 6 power input kW 0 28 1 2 0 33 1 39 0 43 1 78 0 51 2 3 EER 4 47 7 46 4 32 7 34 4 41 7 42 4 24 7 4 capacity kW Boost 4 60 6 00 7 87 9 60 EER Boost 4 47 4 32 4 41 4 24 capacity kW Smart 3 68 4 80 6 30 7 68 EER Smart 5 59 5 40 5 51 5 30 capacity kW Silent...

Page 24: ...apacity kW Silent 7 85 8 67 10 14 11 84 COP Silent 6 80 6 40 6 60 6 53 Air35 Water28 Humidity 80 capacity kW 4 3 11 5 5 3 12 8 6 2 15 7 2 17 5 power input kW 0 57 2 62 0 73 3 1 0 82 3 48 0 97 4 17 EER 4 38 7 48 4 17 7 25 4 29 7 54 4 21 7 44 capacity kW Boost 11 5 12 80 15 00 17 50 EER Boost 4 38 4 17 4 29 4 21 capacity kW Smart 9 20 10 24 12 00 14 00 EER Smart 5 48 5 21 5 36 5 26 capacity kW Silen...

Page 25: ...f the refrigerant of oil and ofother partsmust be done in accordancewithrelevantlocalandnationallegislation Yourproductismarkedwiththissymbol Thismeansthatelectricalandelectronic productsshallnotbemixedwithunsortedhouseholdwaste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant ofoilandotherpartsmustbedonebyaqualifiedinstallerinaccordancewithrel...